![Benchmark ADC16 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/benchmark/adc16/adc16_instruction-manual_2731364016.webp)
ADC16 Instruction Manual
– Rev A
Page 16
AES Digital Audio I/O
The balanced 'AES I/O' digital I/O connectors
follow the Tascam AES/EBU DB-25 standard.
Cables are available from many sources.
These 110-Ω 'AES I/O' connections include
DC-isolation, transformer-coupling, current-
limiting, and diode-protection. Outputs are
designed to drive standard 4 Vpp AES signals
into a 110-Ω load. 110-Ω digital cables are
required when connecting these signals to
other devices. Analog audio cables may
cause data transmission errors, and should
not be used to transmit digital audio.
Data Format = AES/EBU professional
Word Length = 24 bits
Sample Rate = 28 to 50 kHz, 75 to
100 kHz, and 150 kHz to 200 kHz
Clock Source = Internal or External
Data Source = A/D or DAW
The digital audio data at the ADC16's digital
outputs can come from one of two sources:
the ADC16's A/D converters ('A/D') or the
optional interface card ('DAW').
The user can select digital output sources via
the 'SOURCE' buttons on the front panel.
Each set of outputs ( 'AES I/O', 'S/PDIF', and
'Optical') has a 'SOURCE' selection button.
These may be used in any combination.
When DAW is selected as the source, the user
can assign any tracks or sub-mixes of tracks
to the AES outputs.
'AES I/O' DB-25 Pinout
The 'AES I/O' DB-25 pinout follows the
Tascam AES/EBU DB-25 standard:
H = "+" (or hot), C = "-" (or cold), G = GND
The Tascam AES/EBU DB-25 standard
provides four 2-channel inputs and four 2-
channel outputs for a total of 8 channels in
and 8 channels out (on each DB-25
connector). For example, 'Digital Out' '1'
carries channels 1 and 2, and 'Digital Out' '2'
carries channels 3 and 4.
The ADC16 uses all 4 of the digital outputs on
each DB-25 connector (for a total of 16 audio
channels on 8 digital outputs).
The ADC16 only uses one of the 8 available
digital inputs. Digital input 1 on the top DB-
25 connector (audio channels 1 and 2) can be
used as a clock reference input. The ADC16
can lock to an AES digital audio signal on this
input when 'Clock Source' is set to 'AES'.
All digital inputs (including the unused
inputs), are terminated with 110 Ω. 'Digital
In' '2', '3', and '4' are unused on the top DB-
25 connector. 'Digital In' '1', '2', '3', and '4'
are unused on the bottom DB15 connector.