Now unroll and fit the rock wool as shown below. This should sit around the perimeter of the FIXING PLATE.
Under NO circumstances should this fireplace be commissioned without the installation of the Rockwool provided.
Combustible Shelf
This appliance may be fitted below a surround with a combustible shelf providing the following dimensional criteria are
met:
There must be a minimum distance of 250mm from the top of the appliance to the underside of the shelf. The shelf must
not project more than 150mm from the mounting surface of the appliance into the room. If the shelf projects more than
150mm then the distance between the top of the appliance and the underside of the shelf must be increased accordingly;
for every 10mm of projection above 150mm the distance between the fire and shelf must be increased by 20mm
Shelf Protrusion
Min. Distance Between Fire and Shelf
150mm
250mm
160mm
270mm
170mm
290mm
180mm
310mm
190mm
330mm
200mm
350mm