Setting The Day and Time

The following can only be set using the remote control.

Press the power button to turn the unit on.
Press and hold the time setting button        for two seconds to display the time 
and day (no numbers are shown as time has not been set) See Fig 9.
Press the time setting button and the day setting will start to flash. See Fig 10.
Adjust the day setting using the Temp + Temp 

buttons.

Press the time setting button and the hour setting will start to flash, adjust the 
hour using the Temp + and Temp- buttons.
Press the time setting button and the minute setting will start to flash, adjust 
the minute setting using the Temp + and Temp 

buttons

Press the time setting button to set the time and exit the day / time setup.  

Fig 9.

Fig 10.

Setting The Weekly Timer

This timer allows for two ON / OFF periods (M1 / M2) for each day of the week.
The timer can be set using the following procedure:
Press the power button to turn the unit on.
Press and hold the timer mode button       for two seconds to enter the timer 
settings. The settings for the first ON / OFF period (M1) for Monday will be 
shown with the first ON time and hour setting flashing. See Fig 11.
Adjust the hour setting using the Temp + and Temp 

buttons, press the time 

setting button to select the minute, adjust this setting using the Temp + and 
Temp 

buttons.

Press the time setting button and the display will move to the first OFF time 
setting. See Fig 12.
Repeat the above steps to set the first OFF time.
Press the time setting button and the display will move to the second ON / OFF 
period (M2), with the second ON time setting displayed. See Fig 13.
Repeat the above steps to set the second ON / OFF period
Press the time setting button and the display will move onto the first ON / OFF 
period (M1) for Tuesday with the first ON time setting displayed.

Repeat the above steps for Tuesday’s settings and repeat process for 

Wednesday to Sunday settings.

Having confirmed Sunday’s settings exit the timer setting, this can be done by 

not using the remote for 10 seconds and the unit will then default into normal 
operating mode. To activate the timer settings press the timer mode button 
until the timer symbol is displayed on the screen. See Fig 14.

Fig 11.

Fig 12.

Fig 13.

Fig 14.

Note

: The time and day must be set before the timer mode can be activated. The unit can still be operated 

normally when in timer mode using the heater function 

Note

: If the power to the unit is lost then the time / day and weekly timer settings will have to be reprogrammed. 

Содержание 3062

Страница 1: ...1 750 Landscape 1000 Landscape 3 Sided Electric Fires Instructions for operation R1 May 21 ...

Страница 2: ...tandby mode elSB 0 45 W Single stage heat output and no room temperature control No Two or more manual stages no room temperature control No With mechanic thermostat room temperature control No With electronic room temperature control No Electronic room temperature control plus day timer No Electronic room temperature control plus week timer Yes Room temperature control with presence detection No ...

Страница 3: ...rd away from hot surfaces and hot conditions Do not route the power lead in front of the appliance Do not use this fire in rooms that have explosive fumes in them for example petrol or if you are using solvents glue aerosol spray or in flammable paints as these may catch fire This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capa...

Страница 4: ...ns must be in the I position before trying to operate the fire Note Before attempting any operation with the remote control press and slide the battery door on the back of the remote to open the battery compartment Insert the 2 x AAA batteries checking that the and sides of the batteries match the inside of the battery compartment Replace the battery compartment door Manual Operation When using ei...

Страница 5: ...the heat function will automatically turn off This means there is a window open or a cold draft coming into the room past the fire Close the window and press on the manual control panel or the remote control to restart the heater See Fig 4 Fig 4 Note The unit may emit a slight harmless odour and smoke when first used This odour and smoke is normal and is caused by the internal heating parts and wi...

Страница 6: ...ting of the flame effect can also be adjusted This is done by pressing the brightness button and selecting one of the following options Fig 8 H Maximum Setting C Intermediate Setting L Minimum Setting Fig 8 Note The last setting 8 is where the unit cycles through all seven colours Pressing the stops the cycling and holds the unit on one preferred colour a circle will be displayed See Fig 6 When on...

Страница 7: ...ting flashing See Fig 11 Adjust the hour setting using the Temp and Temp buttons press the time setting button to select the minute adjust this setting using the Temp and Temp buttons Press the time setting button and the display will move to the first OFF time setting See Fig 12 Repeat the above steps to set the first OFF time Press the time setting button and the display will move to the second ...

Страница 8: ... once the obstruction has been removed and the heater has cooled If the cut out continues to operate intermittently the heater should be switched off and a service agent contacted Maintenance Warning Always disconnect from the power supply before attempting any maintenance Light Emitting Diode LED This fire is fitted with LED Light Emitting Diode bulbs in place of traditional incandescent bulbs Th...

Страница 9: ...0 EU and the RED standards EN300220 2 EN301489 1 EN301489 3 and EN6247 which covers the essential requirements of the European Radio Equipment Directive 2014 53 EU 200811_1 RoHS stands for Restriction of Hazardous Substances and impacts the entire electronics industry and many electrical products as well The Restrictions of the Use of Certain Hazardous Substances in Electrical and Electronic Equip...

Страница 10: ... or an inadequately installed electric fire d Damage or defects due to mis use accident or unauthorised alterations 4 During the twelve month after the Product has been supplied the Guarantee covers the making good whether by repair or replacement at the Company s option of defects arising from defective manufacture of materials of Product covered in Para 1 all at no cost to the purchaser on the p...

Страница 11: ...11 200811_1 Wiring Diagram ...

Отзывы: