2 Cleaning 

 

Thermolizer  

Once a week, clean the Thermolizer as follows: 

1.

 

Remove and clean Plexiglas doors with 
warm water. 

2.

 

Disconnect from power and remove control 
box from cabinet. 

3.

 

Remove and clean the screen rack angles, 
angle supports, and air duct. 

4.

 

Wipe the cabinet interior clean. 

5.

 

Special attention should be given to cleaning 
the water box (Item 2 of Control Box Assy., 
parts list drawings). Clean the water box as 
follows: 

a.

 

Turn off water to the Thermolizer 
control box.  

b.

 

Remove water reservoir cover. 

c.

 

Empty the water reservoir pan. 

d.

 

Remove water box access cover thumb 
screw and rotate access cover to open 
position. (see Figure 3) 

e.

 

Use a rubber syringe baster to remove 
sediment from the water box. Wipe the 
inside of the water box with a rag. 

f.

 

Add a small amount of water to the 
water reservoir pan. Water should flow 
freely into the water box. If not, clean 
out the water line between the water box 
and the water reservoir pan. Check for 
blockage at the water box inlet hole first. 

g.

 

Close water box access cover and fasten 
with thumbscrew. 

h.

 

Replace water reservoir cover. 

 

 

 

 

Following are some cleaning charts to help keep track of regularly scheduled cleaning. 

 

Содержание TZ17

Страница 1: ...814 44th Street NW Suite 103 Auburn WA 98001 USA Tel 206 322 5474 Fax 206 322 5425 Toll Free US 1 800 578 2547 E mail service belshaw com www belshaw com Thermolizer TZ6 TZ17 Operator s Manual and Tec...

Страница 2: ...Belshaw Bros Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 Thermolizer TZ6 TZ17 OM MN 1257EN iii Contents 1 Operation 1 Control Functions 1 Operation Instructions 1 2 Cleaning 3...

Страница 3: ...adjustment or repair To avoid damaging the machine never use force to assemble disassemble operate clean or maintain it Be careful never to get water or other materials on the floor If anything does g...

Страница 4: ...the operation of this proofer Operation Instructions CAUTION If water is spilled while filling the water pan thoroughly dry all surfaces including the floor Spilled water may cause serious injury los...

Страница 5: ...Belshaw Bros Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 2 MN 1257EN Thermolizer TZ6 TZ17 OM FIGURE 3...

Страница 6: ...Turn off water to the Thermolizer control box b Remove water reservoir cover c Empty the water reservoir pan d Remove water box access cover thumb screw and rotate access cover to open position see Fi...

Страница 7: ...Belshaw Bros Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 4 MN 1257EN Thermolizer TZ6 TZ17 OM Cleaning Dates Write In Drip Pans Cleaned Check or Initial Proofer Box Cleaned Check or Initial...

Страница 8: ...Thermolizer TZ6 TZ17 Technical Supplement Belshaw Bros Inc 814 44th Street NW Suite 103 Auburn WA 98001 USA Phone 206 322 5474 Fax 206 322 5425 E mail service belshaw com http www belshaw com...

Страница 9: ...Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 Thermolizer TZ6 TZ17 TS MN 1258EN iii Contents 1 Installation 1 Unpacking and Assembling the Thermolizer 1 2 Maintenance 3 3 Troubleshooting 4...

Страница 10: ...adjustment or repair To avoid damaging the machine never use force to assemble disassemble operate clean or maintain it Be careful never to get water or other materials on the floor If anything does g...

Страница 11: ...ght claim with the shipping company immediately 6 Clean the humidifier water box and attach to filtered water per plumbing codes in your area Refer to Section 3 for cleaning instructions 7 Install scr...

Страница 12: ...h the one nearest the top of the proofer and work down 12 Turn the control box power switch to the off position see Operation Instructions 13 Connect Thermolizer cord to power source provided from the...

Страница 13: ...Belshaw Bros Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 Thermolizer TZ6 TZ17 TS MN 1258EN 3 2 Maintenance The Thermolizer requires no maintenance other than the daily weekly cleaning...

Страница 14: ...ial the appropriate international access code then 1 206 322 5474 United States When you call please specify the following The model name of the machine The serial number of the machine The voltages p...

Страница 15: ...ective control box power switch Replace power switch LACK OF HUMIDITY OR UNEVEN HUMIDITY Possible Causes What To Do Low water Refill water reservoir Check water is on Defective humidity control Replac...

Страница 16: ...WER WILL NOT RUN Possible Causes What To Do Control box power switch is not on Flip switch to on position Defective blower motor Replace blower motor Defective control box power switch Replace control...