Initial Cleaning
Before using your new Shortening Filter, clean it
as follows:
1. Remove all packing materials.
2.
Remove the pump/motor housing assembly:
a.
Remove the footswitch from the bracket
(See Figure 1-2).
b.
Detach the cord from the plastic retainer
clips (See Figure 1-2).
c.
Remove the hex bolt (See Figure 1-3).
d.
Lift the pump/motor housing off of the
locating pins (See Figure 1-3).
Figure 1-2. Footswitch.
Figure 1-3. Pump motor housing.
CAUTION
Never allow water, steam, or any other
liquid to come into contact with the pump
motor.
3.
Wash the kettle with household dishwashing
detergent, rinse, and dry thoroughly.
4.
Wipe the pump/motor housing and
footswitch with a damp cloth. Never wash
down the pump/motor housing or the
footswitch. Dry thoroughly.
5.
Reassemble the footswitch and housing.
WARNING
You must dry all parts thoroughly.
Moisture causes hot shortening to splatter,
which could cause serious burns.