OTHER EQUIPMENT

 

EZ Melt 18 melter-filter system (purchased separately)

ELECTRICAL INFORMATION

 

Single power connection 

 

208-240V, 50-60hz, 1ph

 

-

Insider with Donut Robot

®

 Mark II/Mark II GP: up to 36 Amps

 

-

Insider with Donut Robot

®

 Mark V/Mark V GP: up to 50 Amps

 

North America models supplied with NEMA#14-50 plug

 

International voltages available

INSTALLATION & CLEARANCE

 

Installation and usage may require approval by local jurisdictions. 
(Customer is responsible for such approval)

 

36" (92 cm) space at rear to allow room for operator, and to allow 
EZMelt 18 Melter Filter to roll out

 

36" (92 cm) at left side (viewed from rear) for operator access to 
the left and rear of the unit

 

29" (74 cm) overhead clearance for air discharge (nominal)

SHIPPING WEIGHT AND DIMENSIONS (estimated)

 

90" W x 43" D x 89" H (229 x 109 x 226 cm)

 

1444 lbs (656 kg), USA Freight Class 175

STANDARDS CERTIFICATION

NSF STD 4 
CSA C22.2

UL197 

UL710B

 

Certified by ETL to UL-197, UL-710B, NSF-4 and CSA C22.2 
standards. (ETL Control #68183)

 

CE models available for European Union and other countries

35" (89 cm)

STOP/START SWITCH

FIRE SUPPRESSION 

MANUAL PULL STATION

WET FIRE 

SUPPRESSION 

CYLINDER

FIRE SUPPRESSION 

CONTROL BOX

ROTO COOLER

DONUT ROBOT

12" (30 cm)

31" (79 cm)

6.5" (16 cm)

POWER 

POWER 

FILTRATION RECEPTACLE

FRYER RECEPTACLE

FRONT

REAR

HOOD/CLEAN AIR ASSEMBLY

AIR DISCHARGE

P

OVERALL HEIGHT:  

91.5" (232 cm)

POWER CORD 72" (183 cm)

PLUG NEMA #14-50 (1-PHASE)

NEMA #6-50P (3-PHASE)

84¼" (214 cm)

Nominal clearance 

for  air discharge 

18" (45 cm) 

P

EZMELT 18 

MELTER FILTER

STANDARD FEATURES - INSIDER CABINET

 

Air recycling system, with fan-assisted grease filter, electronic filter, and odor filters

 

Interlock system to ensure ventilation is active. Fryer is otherwise shut down or 
unable to start

 

Donut Robot® fryer (specify model from list below) and Roto-Cooler

 

Fire suppression system (Pyro-Chem Kitchen Knight II, PLC-240/300). Operates 
automatically, also manually from a pull station

 

Stainless steel construction

 

Removable clear polycarbonate viewing windows

 

Heavy Duty 4" casters (feet optional)

COMPATIBILITY WITH DONUT ROBOT

® 

FRYERS

Insider is compatible only with Donut Robot

®

 Mark II, Mark II GP, Mark V, or Mark V GP

 

For standard size donuts, use Donut Robot

®

 Mark II or Mark V

 

For mini donuts, use Donut Robot

®

 Mark II GP or Mark V GP

 

To make standard size AND mini donuts, use Donut Robot

®

 Mark II or Mark V, along 

with Mini Donut Hopper/Plunger Kit, Part #MK-1502-1

 

See Donut Robot Mark II/Mark V spec sheet for specifications

 

Insider is not compatible with Donut Robot

®

 Gas Mark II/Mark II GP

DONUT ROBOT

® 

FRYERS – CAPACITY ESTIMATES

Standard Donuts

Mini Donuts

Mark II

37

 Dozen/hour

Mark II GP

153

 Dozen/hour

Mark II 

with Minidonut Kit

37

 Dozen/hour

109

 Dozen/hour

Mark V

56

 Dozen/hour

Mark V GP

226

 Dozen/hour

Mark V 

with Minidonut Kit

56

 Dozen/hour

163

 Dozen/hour

Estimates are based on full capacity at frying times of 95 seconds for standard donuts 
and 60 seconds for mini donuts.

Clearance 36" (92 cm) 

for operator

Clearance 36" (92 cm) 

for operator

The Spirit of Excellence

an Ali Group Company

90 Years of Quality Donut & Bakery Equipment 

www.belshaw.com

Phone

 800.578.2547 • (+1)206.322.5474  

Customer Service

 [email protected]   

Technical Support

 [email protected]

©2017

 Specifications are subject to change   

Current version available

 from 

www.belshaw.com/retail

BELSHAW ADAMATIC BAKERY GROUP

  

814 44th St NW, Suite 103, Auburn, WA 98001

Product Line

INSIDER 

Ventless Donut Center

Models

INSIDER/Mark II • INSIDER/Mark V

Page 

2

 of 2

Содержание 22587-20

Страница 1: ...ce for Donut and Bakery Equipment www belshaw com USA Canada 1 800 578 2547 International 1 206 322 5474 Email service belshaw com Web www belshaw com SERIAL NUMBER ITEM NUMBER VentlessDonutCenter Ins...

Страница 2: ......

Страница 3: ...ght claim with the shipping company immediately EQUIPMENT RECORD Please provide the information below when you correspond with us about your machine Purchased by ______________________________________...

Страница 4: ...R DONUT FRYING SYSTEM COMMERCIAL ELECTRIC COOKING APPLIANCE WITH INTEGRAL RECIRCULATING SYSTEM INSTALLATION REQUIREMENTS INSIDER SPECIFICATION SHEET FIRE SUPPRESSION DESCRIPTION INSTALLATION INFORMATI...

Страница 5: ...to another The Insider includes an built in air recycling system and no exterior ductwork is necessary The Insider is designed to attract the interest of passers by With its large window viewing area...

Страница 6: ...rlock system to ensure ventilation is active Fryer is otherwise shut down or unable to start Donut Robot fryer specify model from list below and Roto Cooler Fire suppression system Pyro Chem Kitchen K...

Страница 7: ...ection for restaurant cooking appliances hoods and ducts The Pyro Chem System PLC 240 300 KITCHEN KNIGHT II utilizes a wet chemical agent specifically designed to suppress restaurant cooking fires The...

Страница 8: ...e with NSF International Standard No 4 One of the above models is used in each Insider Materials employed have been found to be able to withstand normal wear penetration of vermin corrosive action of...

Страница 9: ...cordance with a The Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations NFPA 96 b The National Electrical Code ANSI NFPA 70 and c Other codes such as the Internationa...

Страница 10: ...ividual appliance shall be considered as occupying not less than 100 square feet 9 3 m2 3 Net exhaust volumes for hoods shall be permitted to be reduced during part load cooking conditions where engin...

Страница 11: ...ng the control head cover and removing the Fire Damper Safety Pin A signed and dated log of installation and maintenance must be kept on premises for use by authority having jurisdiction ETL UL NFPA S...

Страница 12: ...nsider has been fire tested by UL ETL as a stand alone appliance and is not subject to change The ETL Listing does not allow it to be hardwired or permanently attached to the building structure The Re...

Страница 13: ...Pyro Chem Data Sheet...

Страница 14: ......

Страница 15: ...r Filtration Hood and Fire Extinguishing System Operator s Manual Belshaw Bros Inc 814 44th Street NW Suite 103 Auburn WA 98001 USA Phone 206 322 5474 Fax 206 322 5425 E mail service belshaw com http...

Страница 16: ...06 322 5474 Fax 206 322 5425 Insider OM MN 1852EN iii Contents 1 Operation 1 Startup Run 1 Shutdown 1 In Case of Fire 2 2 Cleaning 3 Cleaning 3 Hand Washing Instructions 4 Automatic Dishwasher Instruc...

Страница 17: ...CERTIFIED PERSONNEL ON A REGULAR BASIS AND THE USE AND MAINTAINENCE OF THE INSIDER IS TO BE IN ACCORDANCE WITH NFPA 96 To avoid damaging the machine never use force to assemble disassemble operate cl...

Страница 18: ...the Start button in for a few seconds while the proper airflow is attained 7 The system must be on to provide power to the air filtration system overhead lights auxiliary outlet fryer and cutter See M...

Страница 19: ...u may activate it manually by pulling the handle on the silver manual pull station located at the back of the Insider to the right of the red fire suppression cylinder 3 Call the Fire Department 4 Per...

Страница 20: ...heavily contaminated with grease or oily sludge They should be inspected at least once every month If a vent cleaning service is used a certificate showing date of inspection or cleaning should be mai...

Страница 21: ...nd grease filter no longer feels slippery Automatic Dishwasher Instructions 1 Put the air cleaner cell on the lower rack of the dishwasher with the airflow arrow pointing up It maybe necessary to remo...

Страница 22: ...ing in the cell This will cause no harm and the sound will quit when the cell has dried Cleaning Windows Sliding Doors 1 Use a mild liquid dishwashing soap and a soft cloth or sponge 2 Dry with soft c...

Страница 23: ......

Страница 24: ...Filtration Hood and Fire Extinguishing System Technical Supplement Belshaw Bros Inc 814 44th Street NW Suite 103 Auburn WA 98001 USA Phone 206 322 5474 Fax 206 322 5425 E mail service belshaw com http...

Страница 25: ......

Страница 26: ...ck Check Inspections 6 Use and Maintenance 6 Fire Suppression System 6 Fire Damper System 13 Carbon Filters 14 Electronic Air Cleaner 14 3 Troubleshooting 15 Troubleshooting 15 1 Insider will not run...

Страница 27: ...CERTIFIED PERSONNEL ON A REGULAR BASIS AND THE USE AND MAINTAINENCE OF THE INSIDER IS TO BE IN ACCORDANCE WITH NFPA 96 To avoid damaging the machine never use force to assemble disassemble operate cl...

Страница 28: ...WARNING To avoid electrocution or other injury turn off the machine s main power before attempting any cleaning disassembly adjustment or repair NOTICE IN CASE OF FIRE Instructions for manually opera...

Страница 29: ...the Mark II V or IX Fryer assembly on the cabinet top and place over the locating pins This properly locates the fryer under the fire suppression nozzles 4 Remove the protective paper and the vinyl fr...

Страница 30: ...Belshaw Bros Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 Insider TS MN 1853EN 3...

Страница 31: ...e inside interlock switch There is a 1 diameter disc that pushes against the top filter The disc and switch are adjustable if required to make the interlock function Shutting the door pushes the top f...

Страница 32: ...s attached to the safety pin for identification Remove the safety pin to arm the damper release mechanism as shown in Illustration C DANGER To avoid causing death or serious bodily harm to building oc...

Страница 33: ...nce inspections Use and Maintenance All filters shall be cleaned or replaced in accordance with the manufacturer s instructions The grease filter and pre filter should be cleaned daily The carbon filt...

Страница 34: ...sert System Maintenance Storage Recharging supplies of wet chemical shall be stored in the original closed shipping container supplied by the manufacturer These containers shall not be opened until th...

Страница 35: ...guishing systems shall be subjected to a hydrostatic pressure test at intervals not exceeding 12 years 1 Wet fire suppression cylinder 2 Auxiliary pressure container Exceptions 1 Auxiliary pressure co...

Страница 36: ...or Installation Fusible links are always used in conjunction with the Model NMCH Mechanical Control Head After mounting the cylinder and control head the fusible link line can be installed The first s...

Страница 37: ...ing the cable to mechanical components The crimp must never be used on a single cable The fusible link line can now be put into a set position by applying tension to the fusible link line This is acco...

Страница 38: ...e cable The fusible link line can now be put into a set position by applying tension to the fusible link line This is accomplished by using a socket on the fusible link line ratchet wheel The ratchet...

Страница 39: ...x and conduit feed the stainless steel cable from the releasing device through the conduit and into the pull station box Feed the cable through the bushing and through the hole provided in the pull ha...

Страница 40: ...wrench to tighten the cartridge into the actuator Remove the pull pin from the hole in the slide plate and install the control head cover Fire Damper System Visually inspect the damper or damage and v...

Страница 41: ...mount of dirt present in the air in you locality The washing frequency best suited for you unit can be determined by examining the dirt collected components at three 3 week intervals As the dirt begin...

Страница 42: ...ou perform repairs yourself or have them performed by anyone other than Belshaw Bros or a service technician authorized by Belshaw Bros you do so at your own risk For factory service return your machi...

Страница 43: ...ut Check fuses located inside electrical enclosure and replace If condition continues look for electrical short Fire suppression system has fired Call the Pyro Chem certified personnel to reset change...

Страница 44: ...d properly or obstruction in filters air flow 1 Hold the Start button in for a few seconds to attain proper air flow 2 Check clean or replace filters 3 Check to see if reed switch is stuck Tap on swit...

Страница 45: ...ge Connection Improper ground Loose Hi Voltage Connection Correct Correct Odor of Ozone Same See Page 25 4 Electronic Air Cleaner Symptoms and Corrections 1 Arcing Noise When an arcing noise is noted...

Страница 46: ...This trouble is not common but when occurring is usually due to either a continuous high voltage leak or discharge or from the absence of a good common electrical ground Refer to checks listed under 1...

Страница 47: ...etected visually Power Supply Check without high volt meter Problem Areas Corrections Excessive dirt build up Wash Large pieces of foreign matter lodged between plates Remove Very dirty insulators Cle...

Страница 48: ...defective one will produce no arc at all or a very weak one Refer to illustration N Trouble shooting Trion power supply Power Supply Check with DC high volt meter Take reading with the high voltage m...

Страница 49: ...Belshaw Bros Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 22 MN 1853EN Insider TS...

Страница 50: ...section please find information relating to Pyro Chem and Kitchen Knight Fire Suppression System In Case of Fire Pyro Chem Contacts Kitchen Knight II Owner s Manual for PCL 300 460 600 Pyro Chem Kitc...

Страница 51: ...ted you may activate it manually by pulling the handle on the silver manual pull station located at the back of the Insider to the right of the red fire extinguisher cylinder 3 Call the fire departmen...

Страница 52: ...x 206 322 5425 Insider TS MN 1853EN 25 To schedule a kitchen style fire suppression test United States Call Pyro Chem at 1 800 526 1079 Or visit their website at www pyrochem com and click on Key Cont...

Страница 53: ...Belshaw Bros Inc www belshaw com Phone 206 322 5474 Fax 206 322 5425 26 MN 1853EN Insider TS 5 Appendix Pyro Chem Kitchen Knight Manual Parts List Drawing Insert Page...

Страница 54: ......

Страница 55: ......

Страница 56: ......

Страница 57: ......

Страница 58: ...ssy for MKII 208 240V 60HZ 1PH Final Assembly Drawing 22587 20 Final Assembly BOM Only Sub Assemblies IN 2008 Mechanical Assembly BOM Only IN 2008GCB Wiring Diagram IN 4021 Electrical Assembly Drawing...

Страница 59: ......

Страница 60: ...Number 22588 21 Insider Assy for MKV 208 240V 50HZ 1PH Final Assembly Drawing 22588 21 Final Assembly BOM Only Wiring Diagram IN 1737 Electrical Assembly Drawing IN 1737 1 Belshaw Adamatic www belsha...

Страница 61: ......

Страница 62: ......

Страница 63: ......

Страница 64: ......

Страница 65: ...ssy for MKII 208 240V 60HZ 1PH Final Assembly Drawing 22587 20 Final Assembly BOM Only Sub Assemblies IN 2008 Mechanical Assembly BOM Only IN 2008GCB Wiring Diagram IN 4021 Electrical Assembly Drawing...

Страница 66: ......

Страница 67: ...agram Ventless Donut Kiosk Insider INSIDER ASSY FOR MKV 208 240V 60HZ 1PH 22888 20 Insider Assy for MKV 208 240V 60HZ 1PH IN 1736 R02 Electrical Assembly Drawing IN 1739 Belshaw Adamatic www belshaw c...

Страница 68: ...ST LOCK 20A 250V HUBBELL 1 IN 0180 310 BLADE PLUG 250V 60A 3P4W VMI 1 MKV 0031 311 POWER DISTRIBUTION BLOCK MARATHON 1 TM634 0233 312 PHTM DIN RAIL 35MMX7 5MMX1FT 1 990 0260F 313 LABEL AUXILIARY 1 IN...

Страница 69: ......

Страница 70: ......

Страница 71: ......

Отзывы: