Using battery backup
The Visit Smart hub is equipped with a battery backup that ensures full
functionality during power loss for at least 48 hours.
Replacing batteries
Unplug the mains power and open the front cover. Replace the old bat-
teries with new ones, see the instructions in the battery compartment for
correct positioning.
Important!
Use 1.5 V AA, LR6 alkaline batteries only. Always
keep batteries out of reach of children. Dispose of
batteries according to your local environmental laws and
guidelines.
Technical information
Power supply
DC 5V
Power consumption
Active < 50 mA, Idle position < 6 mA
Backup battery
2 x 1.5 V AA (LR6) alkaline batteries
Activation
Via test buttons or a Visit monitor
Monitor frequency
315/433.92/868.3 MHz depending on region
Monitor coverage
33 – 77 yd. (30 – 70 m) depending on radio
frequency. Coverage is reduced by walls, large
objects and other radio transmitters.
Bluetooth® frequency
2400 – 2483.5 MHz
Bluetooth® coverage
Up to 33 yd. (30 m). Coverage is reduced by thick
walls and large objects.
Compatible monitors
BE1411 Door transmitter, BE1431 Telephone
transmitter, BE1491 Room monitor, BE1240/1420
Push button transmitter and BE1281/1480
Smoke alarm transmitter