background image

Room Divider Large 3  

Direct Vent Gas Fireplace

Installation manual

 

-  Do not store or use gasoline or other fl ammable vapors and liquids in   

 

 

the vicinity of this or any other appliance.

 

-   WHAT TO DO IF YOU SMELL GAS:

 

 

•   Do not try to light any appliance.

 

 

•   Do not touch any electrical switch; do not use any phone in your    

 

 

    building.

 

 

•   Immediately call your gas supplier from a neighbor’s phone.  

 

 

    Follow the gas supplier’s instructions.

 

 

•   If you cannot reach your gas supplier, call the fi re department.

 

-  Installation and service must be performed by a qualifi ed installer, 

 

 

service agency or the gas supplier.

 

WARNING:

 If the information in these instructions are not 

 

followed exactly, a fi re or explosion may result causing property damage,  

 

personal injury or loss of life.

 

This appliance may be installed in an aftermarket, permanently located home  

 

or mobile home, where not prohibited by local codes. This appliance is only 

 

for use with the types of gas indicated on the rating plate. A conversion kit is 

 

supplied with the appliance.

WARNINGS

 

INSTALLER: 

 

Leave this manual with  

 

 

the appliance.

 

CONSUMER: 

 

Retain this manual for 

 

future reference.

A barrier designed to reduce the risk of burns from the 
hot viewing glass is provided with this appliance and 
shall be installed for the protection of children and other 
at-risk individuals.

HOT GLASS 

WILL 

CAUSE BURNS.

 

DO NOT TOUCH 

GLASS

UNTIL COOLED.

NEVER 

ALLOW CHILDREN

TO TOUCH GLASS.

WARNING

Содержание Room Divider Large 3

Страница 1: ...rmation in these instructions are not followed exactly a re or explosion may result causing property damage personal injury or loss of life This appliance may be installed in an aftermarket permanentl...

Страница 2: ......

Страница 3: ...S LINE INSTALLATION 44 BUILDING IN THE APPLIANCE 49 PLACING OF CERAMIC LOG SET 53 GAS FIRE DECORATION KITS 57 MOUNTING OF FLUE GAS RESTRICTION PLATE 61 CHECK OVERPRESSURE HATCHES 63 VISUAL CHECK OF GA...

Страница 4: ...4 Bell res Installation instructions...

Страница 5: ...l be replaced with the manufacturer s barrier for this appliance 4 Any safety screen guard or barrier removed for servicing the appliance must be replaced prior to operating the appliance 5 Children a...

Страница 6: ...he glass when it is hot 17 DO NOT strike or slam the glass panel 18 DO NOT modify the appliance under any circumstances Any parts removed for servicing must be replaced prior to operating the applianc...

Страница 7: ...nd replace any part of the control system and any gas control which has been submerged in water 25 DO NOT operate the appliance if any log is broken 26 The installation must conform with local codes o...

Страница 8: ...ES in the USA and Canada as follows LISTED VENTED GAS FIREPLACES Room Divider Large 3 LF tested to ANSI Z21 88 2009 CSA 2 33 2009 Vented Gas Fireplace Heaters ANSI Z21 88a 2012 CSA 2 33a 2012 Addenda...

Страница 9: ...sible to install the appliance with either a wall or roof outlet The roof connection must be carried out using a Bell res adapter 5 x 7 to 5 x 8 together with a reducer 5 x 8 to 4 x 6 or using a Bell...

Страница 10: ...re Seal Direct Vent Products 4 x 6 5 and 5 x 8 The appliance in combination with the concentric ue system 4 x 6 and or 5 x 8 rigid and or exible for the brands M G DuraVent Direct Vent Pro Selkirk Dir...

Страница 11: ...Natural gas and Propane gas M G DuraVent Direct Vent Pro concentric ue system See component summary SELKIRK DIRECT TEMP Direct Vent Products concentric ue system See component summary METAL FAB Sure...

Страница 12: ...f the gas supplier Never use combustible materials during the installation During installation of the appliance a clearance of 0 12 in 3 mm should be maintained on all sides of the appliance to allow...

Страница 13: ...he side wall according to gure 1 Minimum clearances to combustible material must be maintained Clearance to combustible ceiling Place a non combustible insulation plate false ceiling with a thickness...

Страница 14: ...ulation board Clearance to non combustible material Always place a non combustible insulation plate false back wall at least 12 mm thick between the appliance and a non combustible rear and side wall...

Страница 15: ...vent discoloration Also an open distance between the replace chimney breast and the ceiling of 2 5 cm over a minimal width of 23 60 cm is suf cient Is also total 46 sq ins 300 cm2 Non combustible insu...

Страница 16: ...clearances are shown in gure 3 to 5 Figure 3 Mantel clearances CLEARANCES 12 Max depth Non combustible insulation plate board 2 Max depth Non combustible insulation plate board 12 Min from opening 2 M...

Страница 17: ...instructions CLEARANCES Figure 4 Top mantel clearances Depth of mantel inch Heigth of mantel inch Non combustible material Insulation plate board Glass front appliance Top of replace opening Side view...

Страница 18: ...igure 5 Side mantel clearances CLEARANCES Depth of mantel inch Width of mantel inch Side of replace opening Non combustible material Insulation plate board Top view Combustible mantel piece Side of re...

Страница 19: ...und the appliance Minimum safe distance 40 1 0 m to ammable materials such as curtains furniture etc in front of the replace Install a non combustible hearth oor stone when the underside of the glass...

Страница 20: ...h deck or balcony 12 in 30 cm B Clearance to window or door that may be opened 12 in 30 cm C Clearance to permanently closed window 12 in 30 cm D Vertical clearance to ventilated sof t located above t...

Страница 21: ...ppliance K Clearance to a mechanical air supply inlet 6 ft 1 83 m L Clearance above paved sidewalk or paved driveway located on public property 7 ft 2 13 m M Clearance under veranda porch deck or balc...

Страница 22: ...24 Pipe Length 46DVA 24 11 36 Pipe Length 46DVA 36 12 48 Pipe Length 46DVA 48 13 60 Pipe Length 46DVA 60 14 8 Pipe Extension 46DVA 08A 15 16 Pipe Extension 46DVA 16A 16 11 17 Adjustable Pipe 46DVA 17T...

Страница 23: ...60 Pipe Length 58DVA 60 114 8 Pipe Extension 58DVA 08A 115 16 Pipe Extension 58DVA 16A 116 11 17 Adjustable Pipe 58DVA 17TA 117 17 24 Adjustable Pipe 58DVA 24TA 118 30 Elbow 58DVA E30 119 45 Elbow 58D...

Страница 24: ...6 Pipe 4DT 06 7 DT 9 Pipe 4DT 09 8 DT 12 Pipe 4DT 12 9 DT 18 Pipe 4DT 18 10 DT 24 Pipe 4DT 24 11 DT 36 Pipe 4DT 36 12 DT 48 Pipe 4DT 48 14 Adjustable Length 4 10 4DT AJ12 16 Telescopic Length 14 22 4D...

Страница 25: ...Direct Temp 5DT AAB 102 Horizontal Insulated Termina on Square 5DT HC 106 DT 6 Pipe 5DT 06 107 DT 9 Pipe 5DT 09 108 DT 12 Pipe 5DT 12 109 DT 18 Pipe 5DT 18 110 DT 24 Pipe 5DT 24 111 DT 36 Pipe 5DT 36...

Страница 26: ...ina on Termina on Cap 4DVT 6 6 Pipe Straight Length assembly 4D6 8 12 Pipe Straight Length assembly 4D12 9 18 Pipe Straight Length assembly 4D18 10 24 Pipe Straight Length assembly 4D24 11 36 Pipe Str...

Страница 27: ...5 x 7 to 5 x 8 Metal Fab 5DBA 102 Horizontal Termina on Square Termina on Cap 5DHT 106 6 Pipe Straight Length assembly 5D6 108 12 Pipe Straight Length assembly 5D12 109 18 Pipe Straight Length assembl...

Страница 28: ...one installation Check whether the wall or roof termination kit to be used exactly matches one of those listed in this installation manual Due to the high temperature of the outer walls approx 300 F...

Страница 29: ...ing the winter months This will help to stop the roof termination from freezing up We recommend using the thermostat room temperature setting on the remote to allow the appliance to cycle VENT INSTALL...

Страница 30: ...NT INSTALLATION ALL SIZES INCLUDE THE LENGTH OF THE ROOF OR WALL TERMINATION Assemble restriction plate Appliance Distance Y Concentric connection min max on appliance is 5 x 7 72 144 Width B 65 mm 2...

Страница 31: ...e restriction plate Appliance Distance Y1 Distance X Distance Y1 Y2 Concentric connection min max min max min max on appliance is 5 x 7 Room Divider 36 396 0 108 72 396 Width B 40 mm Large 3 LF 1 0 11...

Страница 32: ...ON FLEXIBLE CONCENTRIC FLUE 4 x 6 SYSTEM CONNECTION POSSIBILITIES Appliance Concentric ue connection 5 x 7 Assemble restriction plate Appliance Distance Y Concentric connection min max on appliance is...

Страница 33: ...ys at least 2 to 1 Assemble restriction plate Appliance Distance Y1 Distance X Distance Y1 Y2 Y3 Concentric connection min max min max min max on appliance is 5 x 77 8 Room Divider 36 396 0 108 36 396...

Страница 34: ...0 5 1 0 m 0 0 5 m 0 0 5 m 0 0 5 m Large 3 36 108 0 36 18 72 0 18 LF 1 0 3 0 m 0 1 0 m 0 5 2 0 m 0 0 5 m 36 108 0 108 36 108 0 18 1 0 3 0 m 0 3 0 m 1 0 3 0 m 0 0 5 m VENT INSTALLATION Appliance Concen...

Страница 35: ...mble restriction plate Appliance Distance Y Distance X Concentric connection on min max min max appliance is 5 x 7 0 18 0 18 0 0 5 m 0 0 5 m 18 36 0 54 Room Divider Large 3 LF 0 5 1 0 m 0 1 5 m 36 108...

Страница 36: ...scolouring of the column Flammable materials such as curtains should not be placed in the vicinity of the appliance Minimum safe distance 40 100 cm See also chapter CLEARANCES POSITIONING THE APPLIANC...

Страница 37: ...iance and the insulation plate board according to the Chapter CLEARANCES 1 Inlet opening appliance convection air for chimney breast Enclosure 2 Natural convection in the chimney breast Enclosure 3 Ou...

Страница 38: ...board according to the Chapter CLEARANCES 1 Inlet opening appliance convection air for chimney breast Enclosure 2 Natural convection in the chimney breast Enclosure 3 Outlet opening chimney breast Enc...

Страница 39: ...The adjustable feet on the bottom side of the appliance can also be adjusted using an Allen key The oor of the combustion chamber can be reached after the window and the grill around the burner have...

Страница 40: ...i ed insulation plates Move the appliance until it is 5 cm from the rear wall and ensure it is level Place the non ammable insulation plate min 12 mm between the appliance and rear wall The appliance...

Страница 41: ...with the free oating frame support Screw the M8x16 bolts into the wall Turn the ange nuts on the inside on support at the desired height the screws Leave room between the wall support Screw the wall...

Страница 42: ...IONING THE APPLIANCE If not the appliance can be adjusted using the 2 adjustable feet on the bottom side Raise the appliance and slide it over Slide the appliance downwards the bolts Tighten the nuts...

Страница 43: ...iance to gas supply must be performed by a quali ed installer service agency or the gas supplier Follow the local codes IMPORTANT During gas connection take care not to twist the gas regulator block M...

Страница 44: ...and piping against encasement by cement etc Note When the installation of the built in operating unit is not possible one can place the gas regulator block and receiver under the appliance Important K...

Страница 45: ...onnection and thermocouple interrupter manually into the gas regulator block Afterwards carefully fasten a half turn with a spanner Disassembly and assembly of pipes and cables If necessary for mounti...

Страница 46: ...PT Gas regulator block Thermocouple Pilot light pipe 4 mm Flex Thermocouple interrupter Figure 16 Gas regulator block and gas valve Gas and thermocouple connections Figure 17 Gas regulator block Front...

Страница 47: ...on Adjustment Screw Minimum Burner pressure Pilot light connection Figure 18 Gas regulator block Rear Figure 19 Receiver Top Thermocouple voltage current OUT connection yellow Piezo cable connection R...

Страница 48: ...48 Bell res Installation instructions GAS LINE INSTALLATION Figure 20 Receiver AUX connection RESET button RESET button AUX Electrical connection for gas valve rear burner...

Страница 49: ...ckwork must be built up around the appliance In connection with the appliance expanding during burning there must be at least 0 12 3 mm clearance on either side of the appliance Do not build up the br...

Страница 50: ...ron in combination with the 10 cm frame option The mantle iron is screwed on the top panel of the 4 sided 10 cm frame at the factory Do not unscrew this connection Bar set 4x draw bars 2x tension slee...

Страница 51: ...tween the mantle iron and the top of the side panels The side panels should always be easily removable Check that the mantle iron is at right angles to the side panels both left and right Put ceramic...

Страница 52: ...k tester Once the replace has been nished you can now t the frame with the small door to the operating unit not for free oating installation Depending of enclosure After installation in a new replace...

Страница 53: ...pted to the appliance Replacement parts including the ceramic mat are available from your dealer Fitting may only be carried out by a quali ed person Ceramic log set embers vermiculite granules 1 Plac...

Страница 54: ...rner 0 62 in 16 mm Embers and vermiculite must not be placed next to the pilot light burner PLACING OF CERAMIC LOG SET 4 Place the ceramic logs on the burner as shown in gure 21 and gure 22 Natural ga...

Страница 55: ...55 Bell res Installation instructions PLACING OF CERAMIC LOG SET Logs Log no u Log no v Log no w Log no x Log no y Log no z Log no Log no...

Страница 56: ...atural gas burner Figure 22 Log set Room Divider Large 3 LF Position propane burner NATURAL GAS PROPANE GAS Embers must not be placed next to the pilot light burner Keep the burner ori ces unblocked y...

Страница 57: ...57 Bell res Installation instructions GAS FIRE DECORATION KITS Fire Proof Material Size Colours Stone Pebbles 1 12 30 mm Different Crushed Glass 1 12 30 mm Different Stone Pebbles Crushed Glass...

Страница 58: ...d service agency in accordance with the requirements of the manufacturer provincial or territorial authorities having jurisdiction and in accordance with the requirements of the CAN CGA B149 1 or CAN...

Страница 59: ...le burner bed burner and grate around the burner Make sure that the pilot light remains free IMPORTANT Do not place any pebbles glass in front of the pilot light Make sure that the pilot light can bur...

Страница 60: ...rushed Glass must not be placed in front of the pilot light burner Keep the burner ori ces unblocked Keep the back row of slots in the grate open Keep the burner ori ces unblocked Stone Pebbles must n...

Страница 61: ...width B into the ceiling of the combustion chamber To do this see the set up options as listed in gure 7 through 12 Figure 23 Positioning restriction plate Important Ensure that the correct ue gas re...

Страница 62: ...RICTION PLATE The following restriction plates are supplied Dimensions in mm s The size of each plate in mm s is printed on the plates Concentric ue connection appliance 5 x 7 Restriction plate Roof t...

Страница 63: ...ening Check overpressure hatches There are four overpressure hatches in the ceiling of the combustion chamber front IMPORTANT Check that the hatches are loose by lifting a little and carefully letting...

Страница 64: ...ion visually check the gas ame When the re is ignited the ames should be short and blue yellow in colour These ames should gradually increase in height and become more yellow When all ames are yellow...

Страница 65: ...all times freely over the main burner Only in this way is proper ignition of the main burner ensured Ignoring these directions could lead to a dangerous situation ANNUAL MAINTENANCE Check the gas sup...

Страница 66: ...pilot light Dirty electrical contacts in the thermo electrical system for example the thermocouple connection Batteries in receiver or remote control are at SAFETY MEASURES IN THE APPLIANCE Thermo el...

Страница 67: ...lacement of the glass should be done by a licensed or quali ed service person Room Divider Large 3 Unscrew the glass holder at the top a little and leave it in place Pull the side panel forwards along...

Страница 68: ...akage The glass panes must t properly all round the edges of the combustion chamber Check if the fastening strips have been properly mounted all round Check if the compression springs has been replace...

Страница 69: ...Pilot light gas pipe Thermocouple interruptor 8 Wire connecting cable Gas pipe Front burner Gas valve Rear burner AC power adapter 110 VAC option Button RESET Receiver with battery compartment for 4...

Страница 70: ...70 Bell res Installation instructions DIMENSIONS ROOM DIVIDER LARGE 3 Hidden Door 10 cm frame...

Страница 71: ...71 Bell res Installation instructions DIMENSIONS ROOM DIVIDER LARGE 3 Wall mounted 10 cm frame...

Страница 72: ...72 Bell res Installation instructions OPERATING UNIT Dimensions in inches 9 7 12 4 11 3 2 14...

Страница 73: ...tu hr 21 500 9 200 Supply pressure in w c 7 0 11 0 kPa 1 74 2 74 Manifold pressure maximum hot in w c 4 8 10 8 kPa 1 19 2 69 Manifold pressure maximum cold in w c 4 6 10 8 kPa 1 15 2 69 Manifold press...

Страница 74: ...burner 12 333608 Adapter 3 8 bsp x 3 8 O ring 13 333610 Nut 8 mm for gas valve rear burner 14 333611 Olive 8 mm for gas valve rear burner 15 302086 Cut off nipple 4 mm GV 60 16 333601 Cable sw Receive...

Страница 75: ...urner 40 341676 Glass Room Divider Large 3 side 493 x 1067 5 x 4 mm 41 341675 Glass Room Divider Large 3 front side 493 x 372 x 4 mm 42 301669 Tube ceramic glue 43 301593 Black bre glass tape 15 x 3 m...

Страница 76: ...wood set Glow effect black Anthracite ltered Appliance Log set Marble pebbles Marble pebbles set white set grey Set Log no Art no C 325292 Room Divider Large 3 LF 1 331357 1x 2 331358 2x 3 331359 1x...

Страница 77: ...m natural gas to propane WARNING This conversion kit shall be installed by a quali ed service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the...

Страница 78: ...fter a repair or replacement of Warranty parts the warranty period shall be deemed to have started on the date of purchase of the product by the consumer 2 6 If a certain part is eligible for the Warr...

Страница 79: ...es hearth is rst red Article 7 Limitation of Liability 7 1 Interfocos B V makes no express warranties except as stated in this Warranty Interfocos sole obligation and the purchaser s exclusive remedy...

Страница 80: ...Serial number Production date 01 100216 341848 FOR YOUR BELLFIRES DEALER VISIT www nee replaces ca OR www neefoyers ca...

Отзывы: