40
Bell
fi res
Installation instructions
POSITIONING THE APPLIANCE
• Position the gas supply pipe such that it can be easily mounted after installation.
Because the control system is outside the appliance, the gas pipe must lead to where
the operating unit (built in), the gas regulator block (and the receiver) assembly are
fi tted.
• Position the appliance in accordance with the installation instructions in chapter;
CLEARANCES. Use only the specifi ed insulation plates.
Move the appliance until it is ± 5 cm from the rear wall and ensure it is level. Place the
nonfl ammable insulation plate (min. 12 mm) between the appliance and rear wall. The
appliance may not be installed against a fl ammable rear wall.
Attach the appliance to the rear wall with 2 wedge bolts.
WARNING:
Connection of the appliance to gas supply must be performed by a qualifi ed
installer, service agency or the gas supplier. Follow the local codes.
IMPORTANT:
During gas connection, take care not to twist the gas regulator block.
Make sure that both the gas regulator block and the supply pipes are
not subjected to stresses.