background image

Electrical connections diagram for 5-family residences

EN

7

No

te

:   

  A

ny

 ty

pe 

of 

TL

 te

rm

ina

l c

an 

be 

mo

un

ted 

ind

oo

rs.

.

            

 Fo

r

 Fa

m.

 1

, th

e t

er

mi

na

l h

as 

ad

dr

es

s 1

, w

hic

h i

s s

et 

             

by

 th

e p

ro

du

ce

r.

 

             

Th

e a

dd

iti

on

al 

ter

mi

na

ls 

mo

un

ted 

in 

pa

ral

lel 

wi

ll h

av

e t

he 

             

ad

dr

es

s o

f t

he 

ma

in 

ter

mi

na

l

           

 Fo

r

 Fa

m.

 2

,

 3

an

5

, th

e t

er

mi

na

l w

ill 

be 

pr

og

ram

me

d w

ith

            

ad

dr

es

s 2

, re

sp

ec

tiv

ely

 

ad

dr

es

se

s 3

4

 an

5

. S

ee 

Ch

. 6

 

            

of 

th

e u

se

r m

an

ua

l f

or 

TL

 au

dio

-vi

de

o t

er

mi

na

ls.

Note

:    

For residenc

es with 

5 families

 and one entranc

e (

entranc

e 1

), 

             

the outdoor panel has 

address 1

, which is set b

y the produc

er.

             

For multiple entranc

es: 

Entranc

e 2

Entranc

e 3

Entranc

e 4

             

panels 

2, 3 

and

 4

 will be programmed ac

cording t

o the 

             

proc

edure in 

Ch.

 4.6

.

4.4

EN

OUT

 4

OUT

 2

OUT

 3

OUT 1

OUT

 

IN

VCB

GONG

GONG

GONG

+U C/D

GND

Vout

Doorbell

GONG 2

GONG 1

DBL 1

DBL 2

+U C/D

GND

Vin

Doorbell

Fam.

 4 

(

address

 4)

GONG 2

GONG 1

DBL 1

DBL 2

+U C/D

GND

Vin

Doorbell

GONG 2

GONG 1

DBL 1

DBL 2

+U C/D

GND

Vin

+U C/D

GND

Vin

Doorbell

GONG 2

GONG 1

DBL 1

DBL 2

GONG

Fam.

 5 

(

address

 5)

Fam.

 3 

(

address

 3)

Fam.

 1 

(

address

 1)

GONG

Doorbell

GONG 2

GONG 1

DBL 1

DBL 2

+U C/D

GND

Vin

Fam.

 2 

(

address

 2)

+U C/D

GND

Vin

Vout2

GNV

GND

+U

VP

A (

address

 1)

SCU

+U

PR

OG

BA

T

110/230V

OUT1

+U

C/D

GND

Vout

Vcam

Fam 3

Fam 2

Fam 4

Fam 5

Fam 1

AUX

,

BA

T

+-

max.

 

42

Ah/12V

LCK

m

ax

. 2

4V

a.c

./2

4V

d.c

.

EX

IT

S1

2x6Aa.c.

11

0V

a.

c./

50

Hz

23

0V

a.

c./

50

Hz

N L

+U

C/D

GND

Vin

LO

CK

SU

PP

LY

+U

C/D

GND Vout

Содержание PA.1FR02

Страница 1: ...1 Fam Video 2 Fam Video 3 Fam Video 5 Fam Video EN 4 Wires VIDEO OUTDOOR PANELS 1 5 Families for TL door phone systems User manual ...

Страница 2: ...must be performed byAUTHORIZED PERSONNEL DO NOT power the product at 110 230 Va c DO NOT hit the glass screen with hard objects If the glass screen is broken DO NOT touch the product Protect the products against lime and dust during renovation activities EN 1 0 Contents EN 1 Safety instructions 2 Description of the video outdoor panels 4 Installation of the Video Outdoor Panel 5 Use of the video o...

Страница 3: ...24AWG max 50m can also be used 4 Installation of the advanced Video Outdoor Panel VPA EN STEP 1 U C D GND 20 25mm 6mm Vin U C D GND 20 25mm 6mm Vout Wall installation height o 70 175 cm 130 cm 115 cm 160 cm 170cm o 20 o 50 Case aluminum 4 mm chemicallytoughened glass 70º 25º orientable video camera CMOS 1 3 573 H x 597 V 800 TVL video 1 Vpp 75 W PAL IR LEDs 850 nm IR CUTfor night vision 10m TOUCH ...

Страница 4: ...te JP1 Signaling of video monitoring RED LED ON Unmount the module and add name labels STEP 3 1 STEP 3 2 Mount back the family name module STEP 2 Mounting on the wall Flush 5 cm 20 cm JP2 Setting of image recording on DVR DVR ON o 70 o 25 o 25 o 25 o 25 o 30 o 70 OFF ON GNV Vout GND C D U OFF ON DVR RED LED OFF ON DVR OFF ON RED LED o 120 o 30 EN 3 ...

Страница 5: ... connections in the panel Torx Mounting the outdoor panel on the wall Surface Important For both types of mounting the Torx screws for fastening the outdoor panels on the wall will be very well tightened to prevent the anti theft alarm sensor from setting off 4 1 EN STEP 1 STEP 1 1 U C D GND Vout Vout U C D GND GNV GNV EN 4 ...

Страница 6: ...tiple entrances Entrance 2 Entrance 3 Entrance 4 panels 2 3 and 4 will be programmed according to the procedure in Ch 4 6 EN 5 Vout2 GNV GND U VPA address 1 Fam 1 Fam 1 address 1 GONG2 GONG1 DBL1 DBL2 Doorbell U C D GND Vin GONG SCU U PROG BAT 110 230V OUT1 AUX Vcam Vout2 GNV GND U SCU U PROG BAT 110 230V OUT1 AUX Vcam Fam 2 address 2 GONG2 GONG1 DBL1 DBL2 Doorbell U C D GND Vin GONG Fam 1 address...

Страница 7: ...Fam 3 the terminal will be programmed with address 2 respectively address 3 See Ch 6 of the user manual for TL audio video terminals Electrical connections diagram for 3 family residences EN 6 4 3 EN U C D GND Vin GONG 2 GONG 1 DBL 1 DBL 2 Doorbell GONG 2 GONG 1 DBL 1 DBL 2 Doorbell U C D GND Vin Fam 3 address 3 Fam 2 address 2 GONG GONG Vout2 GNV GND U SCU U PROG BAT 110 230V OUT1 Vcam OUT2 OUT3 ...

Страница 8: ...ces Entrance 2 Entrance 3 Entrance 4 panels 2 3 and 4 will be programmed according to the procedure in Ch 4 6 4 4 EN OUT 4 OUT 2 OUT 3 OUT 1 OUT IN VCB GONG GONG GONG U C D GND Vout Doorbell GONG 2 GONG 1 DBL 1 DBL 2 U C D GND Vin Doorbell Fam 4 address 4 GONG 2 GONG 1 DBL 1 DBL 2 U C D GND Vin Doorbell GONG 2 GONG 1 DBL 1 DBL 2 U C D GND Vin U C D GND Vin Doorbell GONG 2 GONG 1 DBL 1 DBL 2 GONG F...

Страница 9: ... Long press the PROG button at SCU 2 Long touch the Fam 1 keyat the VPA2 panel long beep Short touch the Fam 1 key twice Two short beeps confirmation The VPA3 panel with address 3 Long press the PROG button at SCU 3 Long touch the Fam 1 keyat the VPA3 panel long beep Short touch the Fam 1 key three times Three short beeps confirmation The VPA4 panel with address 4 Long press the PROG button at SCU 4...

Страница 10: ...be connected to the grid 110V 230Va c and fully operational 1 Go to the place where the SCU central unit of the installation is mounted Long press 3 sec the PROG button on the SCU The Red LED turns on 2 Take the RFID cards to the outdoor panels To program them approach every card for one second to the RFID area of the outdoor panel For each programmed card the panel issues two short beeps Repeat t...

Страница 11: ...al blows e Unauthorized interventions to any of the components of the installation f Theft fire natural disasters g Lack of protection of the installation components in case of renovation activities 6 Maintenance of the video outdoor panels 7 Warranty EN EN EN 10 2 To delete the RFID access cards from the memory of the panel Long touch the Fam 1 key until the acoustic confirmation of the panel wit...

Страница 12: ...732510 MPI Ciudad de Mexico Mexico ELECTRA is a trademark of ELECTRA Group No 008958332 EUIPO Alicante Spain BELLCOME ELECTRA products are registered as Industrial Models at EUIPO Alicante Spain The products are CE certified Certificate no E307311 ISO 9001 2015 ISO 14001 2015 Certificates no 73 100 4856 73 104 4856 by TÜV HESSEN The products are manufactured under Quality and Environment Management S...

Отзывы: