06/16
4
.
3
Installation of the Power supply unit
Retainer
DIN rail
1
2
3
A3,5 x 32 screw (2 pcs.)
B2,9 x 13 screw (4 pcs.)
Protection lid (2 pcs.)
DIN rail mounting
Wall mounting
The
terminal
will be placed at 155cm
height (recommended height).
4.4 Installation of the video Terminal
Before starting...
POWER SUPPLY -
2 smart
(PS2.VDN.ENW)
RISK OF
ELECTRICAL SHOCK!
è
IMPORTANT! Before connecting the
p
ower supply unit's supply fuses, check the
precision of the connections in the system. Check both visually, and by
measurement with an ohmmeter.
è
IMPORTANT! Install the protection lids of the
p
ower supply unit's connections
before connecting the 2 supply fuses (230V/50Hz).
è
DO NOT TOUCH the wires exiting from the connectors and the terminals of the
power supply unit. Disconnect the fuses (10 A) from the supply's phase and null of
the
p
ower supply unit.
è
ATTENTION! Do not supply components of the installation separately (outdoor
panel, terminals etc.) at tensions higher than 15Vd.c. or directly from the network
(230V/50Hz). DANGER OF ELECTRIC SHOCK and of the door phone system's
destruction.
Surface
mounting
≈
20 cm
Cable lenght
(from the wall)
Door phone cable
Screw
A3,5
×
35(32)
(4 pcs.)
Options
for cable passage
INPUT
: ~230V ± 10% / 50 Hz
/ 0,4 A
OUTPUT
: 28V ± 10%
/ 1,2 A
POWER SUPPLY -
2 smart
(PS2.VDN.ENW)
RISK OF
ELECTRICAL SHOCK!
INPUT
: ~230V ± 10% / 50 Hz
/ 0,4 A
OUTPUT
: 28V ± 10%
/ 1,2 A
1
2