Introduction 

Description 

A bell

free

 video door entry system consists of a door panel, positioned at the entrance of a 

building,  apartment  stations  and  other  telephones,  placed  inside  of  the  building  for  the 
convenience of the occupants and a power supply and controller which are usually located 
inside  an  electrical  cupboard.    The  door  panel  comprises  of  a  two-way  speech  unit,  a 
camera, an LED display and sixteen push buttons 

– which are used by a visitor to initiate a 

call.    The  apartment  station,  which  rings  in  response,  allows  a  two-way  hands  free 
conversation  (a  touch  is  required  to  initiate  the  conversation  and  end  the  conversation) 
whilst the caller can be observed through the integral display.  The operator can selectively 
allow  visitors  access  to  the  building  by  touching  a  pad  on  the  apartment  station  and  so 
electrically releasing the door. 

The  bell

free

  digital  video  door  entry  system  is  suitable  for  any  building  or  entry  point 

addressing a quantity of flats where a standard panel would be larger or more expensive; 
this is typically from 16 flats upwards. 

The bell

free

 digital system is supplied with a dedicated door controller, for each entrance, 

and  a  video  controller  for  every  four  apartment  stations.    The  basic  system  supports  1 
apartment  station  per  address,  and  up  to  3  extension  apartment  stations  (more  with 
additional power supplies).  Multiple entrances can be supported with the addition of one 
panel and one door controller for each entrance. 

Main Features 

●  Enhanced audio for hands free operation 
●  Cat5 cable throughout; no co-ax required! 
●  3.5” Flat screen high resolution TFT colour display. 
●  High resolution CCD colour day/night camera with infrared lamps. 
●  12V d.c. operation 
●  High quality full-duplex speech amplifier. 
●  Automatic picture display while ringing. 
●  Ringer mute function. 
●  Ringer volume control. 
●  Fail safe or fail secure lock releases and magnetic locks (maglock). 
●  Lock release timer. 
●  Tradesman facility (optional). 
●  Facility for exit button and/or fire switch. 
●  Door open indication. 
●  Second camera option. 
●  Up to 3 extension apartment stations per flat. 
●  Mixed systems with BS videophones and BSA audio phones 
●  Multiple entrances supported. 

 
 

 

Содержание bell free

Страница 1: ...ee Colour Apartment Stations Installation Operation Manual This manual applies to the following BFD DIG Digital Door controller Version 1 Builds 1 BF Colour Apartment Station Version 1 Build 1 to 2 BS Colour Videophone Version 2 Builds 1 to 3 BSA Audio Phone Version 1 Build 1 BSC4 Video Controller Version 2 Build 7 ...

Страница 2: ...Apartment Station Digital Entry System PD 166 Issue 1 Installation and Operating Manual Page 2 of 48 bellfree Apartment Station BFD DIG controller BSC4 controller BSA audiophone BS videophone BS Deskphone ...

Страница 3: ...LLER SETTINGS 23 BF APARTMENT STATION SWITCH SETTINGS 25 BS VIDEOPHONE SWITCH SETTINGS 26 TROUBLESHOOTING 27 COMMON FAULTS 27 QUICK FAULT REFERENCE 27 SPECIFICATIONS 30 DIAGRAM A BASIC SYSTEM WIRING OVERVIEW 33 DIAGRAM B BFD_DIG PCB DETAIL 34 DIAGRAM C BFD DIG KEYPAD MATRIX 34 DIAGRAM D BASIC SYSTEM WIRING DETAIL 35 DIAGRAM E BSC4 PCB DETAIL 36 DIAGRAM F BSC4 WIRING DETAIL 37 DIAGRAM G LARGE SYSTE...

Страница 4: ...ng or entry point addressing a quantity of flats where a standard panel would be larger or more expensive this is typically from 16 flats upwards The bellfree digital system is supplied with a dedicated door controller for each entrance and a video controller for every four apartment stations The basic system supports 1 apartment station per address and up to 3 extension apartment stations more wi...

Страница 5: ...5 of 48 System bellfree Colour Apartment Station View Pickup Display Contrast Mute Lock Ringer Volume Symbol Lamp Steady Flashing Mute on off Red Apartment station is muted Doorbell All Flash Pickup end Blue Call in progress Ringing View camera select Lock Green Door is open Touch to release lock ...

Страница 6: ... leaving a blank display The reception AKA Porter or Concierge button calls a pre defined phone dedicated to that location The door or Trades button is used to gain direct access either directly or via a code Call sequence When the resident s address is entered followed by the call button the addressed apartment station will ring and its blue pickup view lamp will flash highlighting the pickup and...

Страница 7: ...de see Extension Apartment Stations below Ringer Mute The resident can mute the ringing sound in the apartment station when they do not wish to be disturbed Ringer mute is activated by touching the mute symbol on the apartment station which then illuminates in red as a reminder Touching the mute symbol a second time will disengage the mute function Ringer Mute only stops the audible ring but the b...

Страница 8: ...n the inside of the door and allow residents to exit freely Momentary operation of this button will operate the lock release for the programmed lock time A Fire switch or other override device may use the same input to hold the door open indefinitely Note Fail secure locks must be continuously rated Trades Facility The trades facility is accessed by pressing the door button An optional time clock ...

Страница 9: ...7 surface and model 5078 flush versions are available Battery back up power supply Model 840 12V 4A DDA panels Contact sales for further information Entrance Panel Important Note Careful consideration should be given to the location of the entrance panel to ensure the best possible lighting conditions for the camera In general strong back lighting of the subject by the sun and sky should be avoide...

Страница 10: ...ed next to a door controller For further details see the bellissimo and Bellcall Manual Gate and Block PD 120 Separately Powered Apartment Stations The limitation of up to 4 apartment stations ringing but only one displaying as indicated in the power supply and cable distance tables on page 13 can be overcome by the use of supplementary power from a 340C Power Supply Requirements The system is pow...

Страница 11: ...readers must be taken into account The following table is a guide to how much equipment a PS4 power supply can safely and reliably feed please contact technical support for other variations Equipment 1 x PS4 can power Comments 4 x BSC4 video controllers with 1 BF apartment station per output 16 apartment stations directly powered Extensions may be added if separately powered by 340C s 1 x BSC4 vid...

Страница 12: ...Cat5 is our short reference for EIA standard UTP Category 5 Unshielded Twisted Pair data cable This is a standard solid core twisted pair cable having 4 pairs 8 cores and no shield The cores are in pairs where Blue and Blue with a White stripe are twisted together as the first pair The other three pairs are similar with main colours Orange Green and Brown Also available and acceptable are UTP Cate...

Страница 13: ...1 x Cat5 Locally powered apartment stations have Auto display extensions are daisy chained 25m to 340C 1 x pair of Cat5 100m to 340C 2 x 1mm2 Door Controller to Video Controller s System Distance Cable Comments All Systems 200m 1 x Cat5 N B maximum length from any camera to any apartment station must be less than 300m Panel to BDF DIG Door Controller System Distance Cable Comments All Systems each...

Страница 14: ...l wiring is carried out using a mixture of Cat5 for the signal wiring and 1mm or greater cores for the power wiring refer to Page 12 for further details It is strongly recommended that a consistent colour code be used throughout such as that indicated on the connection diagram Certain signals must be interconnected using a twisted pair from the Cat5 cable These are clearly marked on the connection...

Страница 15: ...e apartment station unit is removed from the wall mounting box by pushing in the two circular buttons at the bottom and pulling apart once open far enough the two hanging clips will release lift off Replace the apartment station unit by hanging it on to the two hooks at the top of the wall mounting box and then push the bottom of the unit onto the two sprung clips Top bottom and rear cable entry a...

Страница 16: ...s not supplied Videophone Alternative to Apartment Station The BS Videophone is designed to be wall mounted onto plasterboard or other masonry at an optimum height of 1 6m DDA requirements may require this to be lower Remove the top cover of the Videophone which is secured by clips at both sides by using both hands and placing fingers under the edges and using thumb pressure to release the clips I...

Страница 17: ...n exit button Fire officers usually require a minimum of door handle or push bar to open a door on a fire exit route not a thumb turn Most fail secure locks are not continuously rated and if an electrical hold open system is used for say busy times then a continuously rated release must be used Powered bolt shoot bolt or other more secure door locking systems may require the use of separate power ...

Страница 18: ...be connected i e 1 BF apartment station 1 door controller and panel and 1 video controller the remaining equipment can be isolated by unplugging terminal blocks NB Ensure the 1 door and video controller remain interconnected and that the end of line controller is terminated temporarily using the jumpers see page 23 Proceed to test the system by calling the apartment station from the door panel in ...

Страница 19: ...The display will show the first programmable parameter ACOD and then alternating at 1 second intervals will be the value and the parameter name Press the door button to step down through the programmable parameters Press the reception button to step up through the programmable parameters The list rolls over bottom to top and vice versa To change a numeric parameter simply type a new 1 4 digit valu...

Страница 20: ...Type Secr Fail secure lock Requires alternate mechanical means key or thumb turn to open on power failure Safe Fail safe lock Lock opens on power failure CAM2 Second Camera Present No Only 1 camera Yes Second camera present TRAD Door Button Trades Mode None No function pressing the door button is ignored Door Pressing the door button opens the door Code Pressing the door button prompts for the ACO...

Страница 21: ...ing Time Call Time and Ring Effect Enter from 0 to 15 as per the table Setting Ring Time Ring Cadence or Sound Effect 0 5s 1 in 3 1 ring every 3 seconds 1 8s 1 in 3 1 ring every 3 seconds 2 10s 1 in 3 1 ring every 3 seconds 3 15s 1 in 3 1 ring every 3 seconds 4 20s 1 in 3 1 ring every 3 seconds 5 30s 1 in 3 1 ring every 3 seconds 6 40s 1 in 3 1 ring every 3 seconds 7 45s 1 in 3 1 ring every 3 seco...

Страница 22: ...ards Switching compatibility mode to Yes changes the number format for addressing a phone and removes the 3 Second overhang of speech when operating the lock from a phone BS801 audio phones from Build 6 or BC801 or BC801P audio phones from Build 6 and all BSA phones already have number format transparency built in and do not need this switch Default is No set to Yes only when in a mixed BCP1 with ...

Страница 23: ...ital controller they also correspond to the inputs on the BFD8 or BFD72 SW6 Setting Pos Phone 1 Phone 2 Phone 3 Phone 4 0 None None None None 1 1 2 3 4 2 5 6 7 8 3 9 10 11 12 4 13 14 15 16 5 17 18 19 20 6 21 22 23 24 7 25 26 27 28 8 29 30 31 32 9 33 34 35 36 A 37 38 39 40 B 41 42 43 44 C 45 46 47 48 D 49 50 51 52 E 53 54 55 56 F 57 58 59 60 Address Offset SW7 SW7 is an 8 bit switch that is used to...

Страница 24: ...W6 and SW7 Phone addresses up to 6410 Phone 1 output can be set Custom versions will show the custom offset on the build label The use of this jumper precludes the use of Odd Even addressing by PROG pins 1 2 if both are required contact Bell System Technical The jumper is stored on pins 4 5 Custom Alternate Addressing Option Special versions of the BSC4 can be ordered to allow addressing above 641...

Страница 25: ...f Off Off 10 hours Off Off Off Off Indefinite Default setting Disabled means touching the mute symbol has no effect Indefinite the mute is cancelled by touching the symbol again Individual Functions DIP SW2 5 8 SW2 5 Master Slave Which Apartment Station to set Off Master Only or first apartment station per BSC4 output On Slave extension Second and subsequent apartment stations per BSC4 output SW2 ...

Страница 26: ...he symbol again Individual Functions DIP SW2 5 8 SW2 5 Master Slave Which videophone to set Off Master Only or first videophone per BSC4 output On Slave extension Second and subsequent videophones per BSC4 output SW2 6 Auto Display on Ring Videophone display behaviour Off Display during ring Picture is on while ringing stays on when answered On No display during ring Picture is off while ringing c...

Страница 27: ...anel Display Problems No display No power at display check for a minimum of 10V To test display cycle the power on BFD DIG and check for both version numbers displayed BDV1 then V4 0 Display indicates F 1 D connection open circuit Display indicates F 2 D connection no data received D connection shorted to 0V Display indicates Fail Apartment number entered was called but did not respond In a large ...

Страница 28: ...used to verify the data connection to the apartment station Pressing the Test Phone n button should cause the apartment station and extensions if any to ring and the associated Select n Led to light Touching pickup or touching view will cause the Audio On and Select n LED s to light There will be no audio as no door panel is active The display on the apartment station will light up to grey or blue...

Страница 29: ...station Normally closed switch has been used for exit button Video Problems Blank picture when Calling apartment station or Touching view Broken or missing Video or Video connection Cameras incorrectly configured refer to CAM2 setting on page 20 Call is from an audio only panel No picture when calling apartment station Check auto display switch is on See page 25 No picture when touching view CCTV ...

Страница 30: ...m Viewing Angle 92º typical Video Output PAL composite video 1Vpk pk 75 Ohm Resolution More than 330 lines Back light compensation Yes BSC4 Video Controller Size 185mm x 230mm x 42mm Supply Voltage 10 8V min 13 8V typical 15V max Current Consumption 350mA idle 3A max 13 8V BF Colour Apartment Station Size 210mm x 260mm x 60mm Fixing Wall Mounted Supply Voltage 11V minimum local power supply only 2...

Страница 31: ...upply Voltage 230V 50Hz nominal Temperature Range 0 ºC to 50 ºC 340C Power Supply Size 140mm x 60mm x 53mm Output Voltage regulated 13 5V Min 13 8V Nom 14 1V Max Output Current 1A continuous 1 5A peak 5 minutes max Mains Supply Internal Fuse Not user replaceable Supply Voltage 230V 50Hz nominal Temperature Range 0 ºC to 50 ºC 840 Power Supply Battery Backed Size 350mm x 330mm x 80mm Output Voltage...

Страница 32: ...BF Apartment Station Digital Entry System PD 166 Issue 1 Installation and Operating Manual Page 32 of 48 ...

Страница 33: ...BFD DIG Door Controller Up to 50m BSC4 4 way Video Controller BSC4 4 way Video Controller Cat5 requirements 14 pairs optional Exit button 1pair Door monitor 1pair 2nd Camera 2 pair Multiple Cat5 Cables Multiple Cat5 Cables Lock wiring options Lock 0 5A 1 0A 12m 1 pair 1 pair 25m 1 pair 2 pair 50m 2 pair 4 pair 50m 2x1mm 2x1mm All cable MUST be 4 pair data cable Except for power wiring where stated...

Страница 34: ... Time D 4 2 bell BFD DIG free Enhanced Speech Door Controller Display Keypad Status 1 1 Prog 6 HF Prog Vol Speech Vol Panel Speaker Save Lock Power Test Cam2 Audio Video 100 75 High 100 75 High Cam1 Cam2 4 3 2 1 0 Video Gain Label BFD DIG Version No Build No Panel Tone Volume bell System 2010 Speech Unit PM 12V SPKR Exit 12V 12V Door Lock Power 2 2 M M 1 1 S S B B A A Video Camera 1 Camera 2 Video...

Страница 35: ...or Switch optional 2 x 1mm BD10 Display Module D 0V V 7 6 5 4 3 2 1 8 1 4 7 A 2 5 8 0 3 6 9 Z From previous controller To Next controller Power to Display 3 cores each Panel Mic Red Black All signal cable MUST be Cat5 See Cable Specification Cat5 4 twisted pairs data cable One pair in the Cat5 cable This symbol is used to indicate where a twisted pair connection must be used Brn W Brn Org W Org Gr...

Страница 36: ...4 Audio on Select 1 Select 2 Select 3 Select 4 OFF ON Video Termination 4 3 2 1 0 Video Gain Label BSC4 Version No Build No 1 Prog Power Supply SW7 Off On SW6 1 2 3 4 5 6 7 8 1 2 50 100 200 400 800 1600 Set Phone Address Then Add values below to get address 0 AD Mode 1 1 2 3 4 2 5 6 7 8 F 57 58 59 60 2 2 2 2 2 2 1 1 1 1 1 1 B B B B B B A A A A A A Video Video Video Video Video Video 12V 12V Audio ...

Страница 37: ...t BSC4 Brn Brn Brn Brn Brn W Brn W Brn W Brn W Brn W Brn Org Org Org Org Org W Org W Org W Org W Org W Org Grn Grn Grn Grn Grn W Grn W Grn W Grn W Grn W Grn Blu Blu Blu Blu Blu W Blu W Blu W Blu W Blu W Blu 28V Audio Data BSA Audio Phone Brn W Brn Org W Org Grn W Grn Blu W Blu Brn W Brn Org W Org Grn W Grn Blu W Blu Org W Org Grn W Grn Blu W Blu 2 2 2 1 1 1 B B B A A A Video Video Bell 28V 28V Aud...

Страница 38: ...Cat5 Cat5 Cat5 Cat5 Cat5 Cat5 Cat5 2 x 1mm 2 x 1mm Input Passthru Input Passthru Input Passthru Input Passthru Output Input Output Input Output Input 2 x 1mm 2 x 1mm 2 x 1mm 2 x 1mm 2 x 1mm x 4 Monitors x 4 Monitors x 4 Monitors x 4 Monitors BFDxxx Controller BFDxxx Controller BFDxxx Controller BSC4 Controller BSC4 Controller BSC4 Controller BSC4 Controller Detailed Wiring and Power Supply Calcula...

Страница 39: ... units see next Diagram Extension video units must be daisy chain wired to preserve video quality The last or only video unit on the cable requires the Video Terminator ON all other video units must have the Video Terminator OFF 2 1 B A 28V Audio Data BSA Audio Phone Cat5 From Controller To More Extensions Brn W Brn Org W Org Grn W Grn Blu W Blu Org W Org Grn W Grn Blu W Blu Brn W Brn Org W Org Gr...

Страница 40: ...o quality The last or only video unit on the cable requires the Video Terminator ON all other video units must have the Video Terminator OFF Video Bell Bell 28V Audio Data Video 28V 12V Audio Data BF Apartment Station Cat5 From Controller To More Extensions PSU 340C 12V The 28V connection must be made between all units and the controller For maximum cable distance see text Brn W Brn Org W Org Grn ...

Страница 41: ...Bell controller types M M M M S S S S Camera 1 Camera 1 Camera 1 Camera 1 Twisted Pair Through Connection Door Controller Door Controller Door Controller Door Controller From other equipment or Camera From other equipment or Camera To other equipment To other equipment From Camera From Camera Coax Through Connection Twisted Pair Termination Coax Termination 100 75 High 100 75 High 100 75 High 100 ...

Страница 42: ...on to the proximity wiring Alternatively the exit button can be wired to the proximity reader ACT 1000 2000 3000 Proximity Controller or 100e 200e Extender The lock output on an ACT controller is a volt free relay contact so as long as it is not used for another purpose it can be directly connected to the exit input of a bellfree door controller A 2 wire interface is shown but if a common 12V supp...

Страница 43: ...ill be wired to the Bellcode unit in addition to the bellfree wiring Note 2 A 12V connection will be required if the 2 units are not sharing a power supply Taking an Output From a Third Party System For 12V a c systems use an 88 relay and for 12 d c systems use an 89 relay For systems with other lock voltages a relay with a suitably rated coil will be required For systems with a fail safe output t...

Страница 44: ...he lock release or Maglock using the ACT Manuals 2 Leave the bellfree controller set to Fail Secure regardless of the type of release used 3 A normally open exit button can still be fitted to the ACT controller in addition to the bellfree wiring 4 If the 2 units are not sharing a power supply then a connection from bellfree controller Exit to ACT 0V will be required 5 Look for the notes on the ACT...

Страница 45: ...it to Exit wire is only needed if the two units do not share a common power supply Opening a Gate or Locks on Third Party Systems The bellfree door controller is set to fail secure Use COM and NO or COM and NC as required for the gate controller or third party access system bellfree Door Controller bellfree Door Controller Exit Bellcode 200 Controller Lock Exit Lock Coil Coil Com NO NC 89 Relay Vo...

Страница 46: ...BF Apartment Station Digital Entry System PD 166 Issue 1 Installation and Operating Manual Page 46 of 48 ...

Страница 47: ... should only be connected once the system has been fully tested Connection is made by 2 leads with spade terminals observe the correct polarity red to positive black to negative Care must be taken to ensure that the terminals of the battery are not shorted together by metal objects as this may constitute a Fire Hazard The Control Cabinet is IP55 rated to exclude dust and is vented to avoid the bui...

Страница 48: ...al rate numbers Tel 0845 121 4008 Sales and Technical Support FAX 0845 121 4009 E mail sales bellsystem co uk technical bellsystem co uk Website www bellsystem co uk Standards This product complies with European directive 89 336 EEC on Electromagnetic Compatibility and Low Voltage Directive 72 23 EEC Emissions Generic BSEN 61000 6 3 Immunity Generic BSEN 61000 6 1 Low Voltage Generic BSEN 60950 BS...