SECTION 512-730-450
using
24
gauge wire •or 85 feet when using 26
gauge wire..
Refer to Section 512-700-100 for
detailed information on power supply applications.
2.07
The M2FG cord is furnished as part of the
223-type adapter for connecting the power
unit.
Danger:
For safety, securely attach
a retaining clamp to ac outlet using
outlet cover screw BEFORE attempting
to install 85Bl power unit.
The
power unit and any other cord plugged
into the ac outlet should always be
unplugged completely from outlet
BEFORE attempting t o attach or
remove the clamp.
This will prevent
the possibility of a loosened retainer
clamp or metallic outlet cover making
contact with the ac prongs of the
85Bl p o w e r unit when partially
withdrawn from outlet.
Do not use
Page 2
retaining clamp on outlets where cover
mounting screw holds the duplex outlet
in the box.
Warning:
Care should be taken to
trim and dress leads connecting to
low voltage output terminals of 85Bl
power unit to assure that inadvertent
connection to conducting surfaces or
other power source does not occur.
•If more than one power unit is
plugged into a multiple receptacle
power strip, there must be at least
one inch separation between power
units.
Only
UL
listed receptacle
power strips with adequate power
rating shall be used.
A
continuous
terminal power strip that allows the
secondary output terminals of the
power unit to be in close proximity
t o t h e a c l i n e s o u r c e i s n o t
recommended
.•