background image

En

P73220uk

UPS Uninterruptible 

Power Supply

User Manual

P73220uk_Gold_UPSMan  27-05-2002  15:01  Page 1

Содержание F6C325-220V

Страница 1: ...En P73220uk UPS Uninterruptible Power Supply User Manual P73220uk_Gold_UPSMan 27 05 2002 15 01 Page 1...

Страница 2: ...the proper operation of the UPS come into question Please save or recycle the packaging materials The UPS shipping materials were designed with great care to provide protection from transportation re...

Страница 3: ...nt Panel 6 Rear Panel 7 5 Installation 9 6 Operation 10 7 Alarm 11 8 Software Options 11 9 USB Interface Port 12 10 RS232 Interface Port 14 11 Battery Replacement 15 12 Troubleshooting 17 13 Storage 1...

Страница 4: ...incur computer repairs lost data and downtime Solution A Belkin Uninterruptible Power Supply UPS with Automatic Voltage Regulation AVR Typical Stand by UPS units do not have AVR to increase the output...

Страница 5: ...ible shock from touching two surfaces with different electrical grounds Connect the equipment to a three wire AC outlet two poles plus ground The receptacle must be connected to an appropriate circuit...

Страница 6: ...s Battery output is drawing more power than the UPS can provide 4 3 REPLACE BATTERY Red Battery is too weak or bad If UPS is in On Battery mode this means the UPS is just testing the condition of the...

Страница 7: ...sential equipment and reset the circuit breaker 4 10 BATTERY BACK UP OUTLETS Data sensitive equipment such as a computer monitor and external drive should be powered by these outlets Battery power is...

Страница 8: ...tery Back up outlets 4 5 Interface Port USB or RS232 Depending on model 4 6 Telephone Fax Modem or 10 base T network Protection 4 7 Battery Replacement Door 4 9 AC Breaker Circuit Breaker 4 8 AC Input...

Страница 9: ...Belkin Components for details of a local reseller 5 4 Connect Computer Interface Belkin Sentry Bulldog Shutdown Management Software and the USB or RS232 cable depending on model can be used with this...

Страница 10: ...on when the UPS is supplying power to the connected loads The UPS can be utilised as a master on off switch for the protected equipment NOTE The UPS maintains the battery charge when in the off positi...

Страница 11: ...Belkin Sentry Bulldog Shutdown Management Software or as stated in step 6 3 The alarm stops when the UPS returns to line normal operation 7 1 LOW BATTERY rapid alarm In backup mode when the battery en...

Страница 12: ...up procedure Charge the UPS 2 4hours before installing the software Connect the supplied RS232 serial cable excluding 325VA Series to the UPS and connect the other end to a designated port on the PC T...

Страница 13: ...n For Alarm 10 Voltage Sensitivity To Improve Transfer Time and Avoid Effect Of I P Distortion 11 Outlet Relay ON OFF Set Delay Time to Control Outlet Relay On Off 12 Next Shutdown Time To Next Schedu...

Страница 14: ...condition 3 Monitoring inverter status 4 Monitoring UPS status 5 Monitoring the utility status 6 Providing the power switch function for the computer to turn on off the utility on schedule To save po...

Страница 15: ...e battery compartment cover down Diagram b 11 1 3 Grasp the battery and slide it partially out Then grab the battery firmly and remove the battery wires will disconnect as the battery is pulled out Di...

Страница 16: ...contact Belkin Components Diagram a Diagram b Slide the battery compartment cover Diagram d Slide the battery back in Avoid pinching the wires Diagram c Slide the battery partially out Diagram e Slid...

Страница 17: ...g the power cord Replace the breaker Normal condition Recharge the UPS at least 4 hours Remove some unnecessary loads Replace battery Remove the non critical loads Replace battery 13 0 Storage Conditi...

Страница 18: ...ad Type Protection Automatic self test and discharge protection replace battery indicator Typical Recharge Time 4 hours to 90 of full capacity Sealed maintenance free lead acid BATTERY PHYSICAL ALARM...

Страница 19: ...load Type Protection Automatic self test and discharge protection replace battery indicator Typical Recharge Time 4 hours to 90 of full capacity Sealed maintenance free lead acid BATTERY PHYSICAL ALAR...

Страница 20: ...SET FORTH ABOVE ARE EXCLUSIVE IN LIEU OF ALL OTHERS WHETHER ORAL OR WRITTEN EXPRESSED OR IMPLIED BELKIN SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES O...

Отзывы: