The length of the intake and exhaust pipes is 100 cm
to 200 cm, as shown in Figure 7. The piping must be
arranged in the ascending direction
。
The Exhaust Cowl
(
air inlet and outlet
)
Installation
Select a flat mounting surface so that combustion air
can enter from all sides. Drill one
hole of φ83.
Seal
(Fig. 8-8), with the plane facing the exhaust cowl.
Wear the fixing clip before installing the exhaust
pipe (Figure 8-3). Pay attention to the installation
of the smoke cap upwards
。
20mm at the end of the exhaust pipe should be
compressed, do not straighten. Insert the exhaust pipe
into the exhaust cowl interface
(
Figure 8-10
),
as
deep as possible
。
Try to fix the clips on the top,
tighten.
Place the air intake pipe (Figure 8-2) over the
exhaust cowl tooth (Figure 8-11). Set on the fixed
clip
(
Figure8-7
)
, tighten.
Secure the exhaust cowl with 6 screws (Figure 8-9).
Use 2 screws to fix the exhaust cowl.
Fix the exhaust pipe on the side wall with mounting
clip.
Connect Air Inlet Pipe to The Heater
20mm at the end of the exhaust pipe should be
compressed, do not straighten.
Try to insert the exhaust pipe on exhaust port as deep
as possible
。
fix the clip on top, tighten.
Place the air intake pipe (Figure 9-3) over the air
inlet port (Figure 9-5). Set on the fixed clip
(Figure9-6
)
, tighten.
Warm Air Intake
The warm air intake is drawn in by the heater. There
must be a total area between the room and the heater
not less than 150cm2 opening.
Ensure that the warm air intake is not contaminated by
the engine or heater exhaust, if necessary, with
structural isolation measures.
Warm Air Distribution
Most of the warm air is imported into the floor area
of the living compartment through the bellows.
The four air outlets on the heater are connected to
the φ65 bellows. Use only pressure piping that meets
the quality requirements of the Belief. Other pipes