Fault Lock Status Debug Method
Fault
Code
Fault Name
Fault Debug Method
43
Water overheat
a.Check whether water depletion in the tank
b.Check if the sensor is in good condition
c.Check whether air outlet is blocked
44
Water overheat switch protection.
a.Check whether air outlet is blocked
b.Check water overheat switch
45
Overheating fault
a.Check whether air outlet is blocked
b.Check water temperature sensor
c.Check warm air sensor
51
Communication fault
Check interconnecting cable
71
Gas valve failure
Check gas valve coil and lead wire
72
Gas valve power failure
Replacement motherboard
81
Combustion support fan disconnection
Check combustion air blower
82
Combustion support blower boot failure
a.Check the blower motor lead wire
b.Check combustion air blower
83
Combustion support blower spindle speed too
low
Check combustion air blower motor
84
Warm air blower motor disconnection
Check warm air blower motor
85
Warm air blower motor boot failure
Check the blower motor lead wire
Check warm air blower motor
86 Warm air blower spindle speed too low
Check warm air blower motor
91
Ignition coil fault
Check ignition coil and lead wire
92
High voltage power supply fault
Replacement motherboard
93
High voltage power supply fault
Replacement motherboard
94
Gas valve power failure
Replacement motherboard
110
Window alarm
Check window switch interconnecting cable
120
Low voltage alarm
Recommended charging
220
220V No connection
Check alternating 220V power supply system
Table 2 to continue