![Belden Thinklogical TLX48 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/belden/thinklogical-tlx48/thinklogical-tlx48_product-manual_2725639015.webp)
15
TLX48 2RU Matrix Switch Product Manual
thinklogical
Rev. B, May 2022
Connecting to the TLX48 2RU Matrix Switch
Thinklogical’s line of TLX, Velocity and Q-Series Extenders come in both multi-mode and single-
mode fiber-optic cable versions.
Thinklogical’s proprietary multiplexing technology combines video, audio and peripheral data on a single
data stream for up to 80km over a single-mode fiber.
The TLX48 2RU is compatible with the following Thinklogical
®
products:
•
Single- & Multi-Mode
TLX 10G KVM and Video
Extenders
(10G to 10G only)
•
Single- & Multi-Mode
Velocity/Q-Series 6G KVM and Video
Extenders
(6G to 6G only)
•
SDI Xtreme 3G+ Extenders
•
Hot-Key Manager / System Management Portfolio
•
Standard
TLX Matrix Switch ASCII Interface
(via RS-232 port or via Network port)
•
Standard
TLX Matrix Switch IP Address Configuration Procedure
•
Standard
TLX Matrix Switch SNMP Traps
Ethernet Control
If the TLX48 2RU KVM Matrix Switch is to be controlled via Ethernet, it will require a
static IP address
.
This value can be set via the DIP switch located on the front of the Annunciator (ANNC) Module. Factory
default setting is:
192.168.13.15
(00000000).
TLX48 2RU DIP Switch Settings
The simplest network connection is an isolated network with only the TLX48, the control server, and any
control clients using static IP addresses. The TLX48 can be set to any of the above settings. The
Control
Server
must be at
192.168.13.9
, and the
Control Clients
can then be set to any other addresses in the
192.168.13.X
subnet.
If static IP addresses for the control server and its clients are not possible, then the control server will
require two (2) network interfaces, with one interface set to the static address
192.168.13.9
and dedicated
to the TLX48 2RU KVM Matrix Switch(s), while the other network interface can be configured as required
by the facility's network administrator.
The Annunciator Module is a line-replaceable unit. Always ensure proper DIP Switch settings when
replacing an Annunciator Module.