Installation SPIDER-SL
Release 06 01/2020
Qualification requirements for personnel
Only allow qualified personnel to work on the device.
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the
prerequisite for grounding and labeling circuits, devices, and systems
in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.
Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
National and international safety regulations
Verify that the electrical installation meets local or nationally applicable
safety regulations.
Grounding the device
The device is grounded by a 3-pin terminal block.
Use a wire diameter for the ground conductor that is no smaller than
the diameter of the supply voltage connection, however of at least
0.5 mm² (AWG20).
Shielding ground
The shielding ground of the connectable twisted pair cables is connected
to the ground connection as a conductor.
Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.