34
Installation SPIDER-SL
Release 06 01/2020
EMC and immunity
Note:
Use shielded data cables for gigabit transmission via copper
cables. Use shielded data cables for all transmission rates to meet the
requirements according to EN 50121-4 and marine applications.
EMC interference
emission
Radiated emission
FCC 47 CFR Part 15
Class A
EN 55032
Class A
Conducted emission
FCC 47 CFR Part 15
Class A
EN 55032
Class A
EMC interference
immunity
Electrostatic discharge
EN 61000-4-2
IEEE C37.90.3
Contact discharge
±4 kV
EN 61000-4-2
IEEE C37.90.3
Air discharge
±8 kV
Electromagnetic field
EN 61000-4-3
80 MHz ... 1000 MHz
max. 10 V/m
Fast transients (burst)
EN 61000-4-4
IEEE C37.90.1
DC supply connection
2 kV
EN 61000-4-4
IEEE C37.90.1
Data line
4 kV
Voltage surges - DC supply connection
EN 61000-4-5
line/ground
2 kV
EN 61000-4-5
line/line
1 kV
Voltage surges - data line
EN 61000-4-5
line/ground
1 kV
Conducted disturbances
EN 61000-4-6
150 kHz ... 80 MHz
10 V
Immunity
IEC 60068-2-6, test Fc
Vibration
5 Hz ... 8.4 Hz with
3.5 mm amplitude
8.4 Hz ... 150 Hz with 1 g
IEC 60068-2-27, test Ea
Shock
15 g at 11 ms