42
Installation RSP20/25/30/35
Release 18 09/2021
For
every
supply voltage to be connected, perform the following steps:
Remove the terminal connector from the device.
Connect the protective conductor with the clamp.
Connect the wires according to the pin assignment on the device with the
clamps.
Fasten the wires in the terminal block by tightening the terminal screws.
You find the prescribed tightening torque in chapter:
“General technical data” on page 54
With a non-redundant supply of the supply voltage, the device reports the
loss of a supply voltage. You can prevent this message by changing the
configuration in the Management.
2.5.3
Supply voltage with the characteristic value CC
You will find information on the characteristic values here:
“Device name and product code” on page 24
You have the option of supplying the supply voltage redundantly, without
load distribution.
Both supply voltage inputs are uncoupled.
Figure 6: Supply voltage with the characteristic value CC: 2-pin terminal block with
screw locking
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment
DC voltage
Rated voltage range DC:
24 V DC ... 48 V DC
Voltage range DC incl.
maximum tolerances:
18 V DC ... 60 V DC
+
Plus terminal of the supply voltage
−
Minus terminal of the supply
voltage
Table 9:
Supply voltage with characteristic value CC: type and specification of the
supply voltage, pin assignment
−
+
Содержание HIRSCHMANN RSP20
Страница 70: ......