32
Installation RSP20/25/30/35
Release 18 09/2021
1.6
Display elements
After the supply voltage is set up, the Software starts and initializes the
device. Afterwards, the device performs a self-test. During this process,
various LEDs light up.
1.6.1
Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
Applies to software releases
before
02.0.00:
LED
Display
Color Activity
Meaning
Power Supply voltage
—
none
Supply voltage is too low
yellow lights up
Device variants with redundant power
supply:
Supply voltage 1
or
2 is on
flashes 4 times
a period
Software update is running. Maintain the
power supply.
green lights up
Device variants with redundant power
supply:
Supply voltage 1
and
2 is on
Device variants with single power supply:
Supply voltage is on
RM
Ring Manager
—
none
No redundancy configured
green lights up
Redundancy exists
flashes 1 time
a period
Device is reporting an incorrect
configuration of the RM function
yellow lights up
No redundancy exists
ACA
Storage medium
ACA31
—
none
ACA storage medium not connected
green lights up
ACA storage medium connected
flashes 3 times
a period
Device writes to/reads from the storage
medium
yellow lights up
ACA storage medium inoperative
LED
Display
Color Activity
Meaning
Status Device Status
—
none
Device is starting and/or is not ready for
operation.
green lights up
Device is ready for operation.
Characteristics can be configured
red
lights up
Device is inoperative
flashes 1 time
a period
The boot parameters used when the
device has been started differ from the
boot parameters saved.
Start the device again.
Status
RM
ACA
Power
Содержание HIRSCHMANN RSP20
Страница 70: ......