5 Technical Data
41
Version 05 07/2014
Repeater
OZD Genius G12
OZD Genius G12-1300
Ord. code
933 989-021
934 233-021
Voltage/power supply
Operating voltage
24 V DC (19 … 35 V DC), non-interchangeable, Safety extra-low
voltage
Current consumption
200 mA
Power consumption
4.8 W
Signaling contact
Maximum switch voltage
30 VDC; 42 VAC (safety extra-low voltage)
Maximum switch current
1.0 A
Maximum switching capacity
30 W (resistive load)
Signal transmission
Transmission rate
153.6 kBit/s, 76.8 kBit/s, 38.4 kBit/s
Cascadability
not limited
Signal processing time
Approx. 800 ns at 153,6 kBit/s
(any input /output)
Approx. 1400 ns at 76,8 kBit/s
Approx. 2500 ns at 38,4 kBit/s
Electrical port
Input/output signal
Genius bus
Genius cable
- Length
< 250 m
- Attenuation at 1 MHz
< 8 dB for 150 ž cable
< 5 dB for 100 ž cable
Connection capability
Max.32 terminal data devices
Terminator
Must be attached outside to connector
Electrical isolation
– Shielding in / Shielding out
Yes
– Data lines / Housing
Yes
Optical interface
Typ. wavelength
860 nm
1310 nm
Launchable optical power
– into fiber E 10/125
–
–19 dBm
– into fiber G 50/125
–15 dBm
–17 dBm
– into fiber G 62.5/125
–14 dBm
–17 dBm
– into fiber S 200/230 (HCS
®
)
–10 dBm
–
Receiver sensitivity
–26 dBm
–27 dBm
Transmission distance with 2 dB
1)
or 3 dB
2)
system reserve / line attenuation
– with fiber E 10/125 (0.5 dB/km)
–
0 - 10 km / 8 dB
1) 3)
– with fiber G 50/125 (1.0 dB/km)
–
0 - 7 km /10 dB
2)
– with fiber G 62.5/125 (1.0 dB/km)
–
0 - 7 km / 10 dB
2)
– with fiber G 50/125 (3.0 dB/km)
0 - 2.7 km /11 dB
2)
–
– with fiber G 62.5/125 (3.5 dB/km)
0 - 2.6 km /12 dB
2)
–
– with fiber S 200/230 (HCS
®
) (8.0 dB/km)
0 - 1.5 km /16 dB
2)
–
Optical connector
BFOC/2.5 (ST
®
)
5 Technical Data
3) The specified distance allowed between two OZD Genius G12-1300 must not be exceeded regardeless of the optical power budget.