40
Installation MS20/MS30
Release 13 09/2019
1.6.1
Device status
These LEDs provide information about conditions which affect the operation
of the whole device.
If the manual adjustment is active on the signal contact, then the error display
is independent of the setting of the signal contact.
P – Power (green LED)
Glowing green
Internal supply voltage present.
Not glowing
Internal supply voltage is too low.
P1 – Power 1 (green LED)
Glowing green
Supply voltage 1 is present.
Not glowing
Supply voltage 1 is less than 18 V.
P2 – Power 2 (green LED)
Glowing green
Supply voltage 2 is present.
Not glowing
Supply voltage 2 is less than 18 V.
RM – Redundancy Manager (green/yellow LED)
Glowing green
RM function activeredundant port disabled.
Glowing yellow
RM function active, redundant port enabled.
Not glowing
RM function not enabled.
Flashing green
Incorrect configuration of the HIPER-Ring (e.g. the ring is not
connected to the ring port).
RUN – BOOT/RUN (green LED)
Glowing green
System is ready for operation.
Flashing green
System is booting.
Not glowing
System is in reset mode.
RL1 – Relay 1, signal contact (red/yellow LED)
Glowing red
Signal contact 1 is open, i.e. it is reporting an error.
Glowing yellow
Signal contact 1 is open, the "Manual Setting" is active.
Not glowing
Signal contact 1 is closed, i.e. it is not reporting an error.
RL2 – Relay 2, signal contact (red/yellow LED)
Glowing red
Signal contact 2 is open, i.e. it is reporting an error.
Glowing yellow
Signal contact 2 is open, the "Manual Setting" is active.
Not glowing
Signal contact 2 is closed, i.e. it is not reporting an error.
RUN, 1 – display saving processes of the AutoConfiguration Adapter (ACA)
Flashing alternately
Error during saving process.
LED's flash synchronously
2× a second
Loading configuration from the ACA.
LED's flash synchronously
1× a second
Saving the configuration in the ACA.