1.3.2
Media modules
The MICE media modules form the interface of the device to the LAN. They
can be attached in the
Basic module MS20-...
Basic module MS30-...
They differ with regard to the number of interfaces and the media type. The
different interfaces of the media modules provide you with the following
interface-specific functions:
Specific functions of TP/TX interface
Link Control
Auto Polarity Exchange
Autonegotiation
Autocrossing (device may be connected with a crossed-over or an un-
crossed cable)
Specific functions of F/O interface
Link Down monitoring
Transceiver-specific (AUI-specific) functions
Collision recognition
Collision test (SQE)
Protection from permanent network connection (Jabber Control)