7.5
Climatic conditions during operation
7.6
Climatic conditions during storage
MACH102-24TP-F
MACH102-24TP-FR
2 × Combo ports (alternatively 100/1000-Mbit/s F/O slot or 10/100/
1000 Mbit/s RJ45 port)
24 × 10/100 Mbit/s twisted pair, RJ45 socket
Media modules
M1-8TP-RJ45
8 × 100 Mbit/s twisted pair, RJ45 socket
M1-8TP-RJ45 PoE
8 × 100 Mbit/s twisted pair PoE, RJ45 socket
M1-8MM-SC
8 × 100 Mbit/s Multimode, Duplex SC connector
M1-8SM-SC
8 × 100 Mbit/s Singlemode, Duplex SC connector
M1-8SFP
8 × 100 Mbit/s, SFP slot
Climatic conditions during operation
Ambient air temperature
a
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
Standard
up to 6562 ft ASL
(2000 m ASL)
+32 °F ... +122 °F (0 °C ... +50 °C)
Maximum inner temperature of
device (guideline)
+203 °F (+95 °C)
Humidity
10 % ... 95 % (non-condensing)
Air pressure
min. 600 hPa (+13123 ft; +4000 m)
max. 1060 hPa (-1312 ft; -400 m)
Table 11: Climatic conditions during operation
Climatic conditions during storage
Ambient temperature
-4 °F ... +185 °F (-20 °C ... +85 °C)
Humidity
5 % ... 95 % (non-condensing)
Air pressure
min. 600 hPa (+13123 ft; +4000 m)
max. 1060 hPa (-1312 ft; -400 m)
Table 12: Climatic conditions during storage