Installation MACH102
Release 07 12/2020
29
2.1.4
Signal contact “FAULT”
Figure 14: MACH102 device, front view
1 - Signal contact
Connect the signal contact via a 2-pin terminal block with screw lock.
The signal contact (“FAULT“, pin assignment of terminal block
see
figure 15
) is used to monitor the device function, and thus supports
remote diagnostics. You can specify the type of function monitoring in the
management.
You can use the Management to set the signal contact manually and thus
control external devices.
The potential-free signal contact (relay contact, closed circuit) reports
through a break in contact:
The detected failure of at least one of the two supply voltages
(supply voltage 1 or 2 is below the threshold value).
A detected continuous malfunction in the device.
The detected defective link status of at least one port. The link state can
be masked for each port in the graphic user interface. In delivery state,.
link monitoring is inactive.
Exceeding or falling below the set temperature threshold values.
Removal of the ACA22.
The following condition is also reported in RM mode:
Ring redundancy guaranteed. By default, there is no ring redundancy
monitoring
Connecting the terminal block
Pull the terminal block off the device and connect the signal lines.
Figure 15: 2-pin terminal block
1
FAULT