background image

 
 
Assembly Instructions  
Field attachable cable plug/socket, 
A-coded M12, straight type with 
screw terminals, IEC 61076-2-101 

 

ELWIKA 5012 PG7  

ELWIST 5012 PG7 

933-175-

 

 

933-167-

 

 

ELWIKA 4012 PG7 

ELWIST 4012 PG7 

933-172-

 

933-165-

 

ELWIKA 4012 K PG7  

ELWIST 4012 K PG7 

933-726--

 

933-728-

 

ELWIKA 4012 PG7 TOPAS 

 

933-173-

 

 

          

                                            

                         

 

IP 67 

 

Cable specification: 
Cable diameter                                               4.0 

 6.0 mm 

Conductor size Solid-/stranded wire        max. 0.75 mm² 

 

CAUTION!

 

Not for current interrupting!

  

 

We have checked that the contents of the technical publication agree with the 
hardware and software described. However, it is not possible to rule out devia-
tions completely, so we are unable to guarantee complete agreement. However, 
the details in the technical publication are checked regularly. Any corrections 
which prove necessary are contained in subsequent editions.  
We are grateful for suggestions for improvement. We reserve the right to make 
technical modifications. Permission is not given for the circulation or reproduc-
tion of this document, its use or the passing on of its contents unless granted 
expressly. Contravention renders the perpetrator liable for compensation for 
damages. All rights reserved, in particular in the case of patent grant or regis-
tration of a utility or design. 

 

© 2021 Belden Inc.  

 

Manuals are protected by copyright. All rights reserved. 
 
Belden reserves the right to change the contents of this document without 
prior notice. Belden can give no guarantee in respect of the correctness or 
accuracy of the information in this document 

 

Note 

 

We would point out that the content of these operating instructions is  
not part of, nor is it intended to amend an earlier or existing agreement, 
permit or legal relationship. All obligations on Belden arise from the  
respective purchasing agreement which also contains the full warranty 
conditions which have sole applicability. These contractual warranty 
conditions are neither extended nor restricted by comments in these  
operating instructions. 

We would furthermore point out that for reasons of simplicity, these  
operating instructions cannot describe every conceivable problem  
associated with the use of this equipment. Should you require further 
information or should particular problems occur which are not treated  
in sufficient detail in the operating instructions, you can request the  
necessary information from your local Belden sales partner or directly  
from the Belden office

 
 

Safety Instructions 

 

This manual contains instructions which must be observed to ensure your own 
Personal safety and to avoid damage to devices and machinery. The instructions 
are highlighted with a warning triangle and are shown as follows according to  
the degree of endangerment: 

 

     

 Danger!

 

means that death, serious injury or considerable damage to property 

will 

result if the appropriate safety measures are not taken. 

     

 Warning!

 

means that death, serious injury or considerable damage to property 

can 

result if the appropriate safety measures are not taken 

     

 Caution!

 

means that light injury or damage to property can result if the appropriate 
safety measures are not taken. 

Note:

 

is an important piece of information about the product, how to use the  
product, or the relevant section of the documentation to which particular 
attention is to be drawn. 

 

Staff qualification requirements 

 

Note:

 

Qualified personnel, as understood in this manual and in the warning signs,  
are persons who are familiar with the setup, assembly, startup, and operation  
of this product and are appropriately qualified for their job. This includes, for  
example, those persons who have been: 

 

-

 

trained or directed or authorized to switch on and off, to ground and to label 
power circuits and devices or systems in accordance with current safety 
engineering standards; 

-

 

trained or directed in the care and use of appropriate safety equipment in 
accordance with the current standards of safety engineering; 

-

 

trained in providing first aid. 

 

 
Certified usage

 

Please observe the following: 

     

 Warning!

 

The device may only be employed for the purposes described in the catalog 
and technical description, and only in conjunction with external devices 
andcomponents recommended or approved by Belden. The product can only 
be operated correctly and safely if it is transported, stored, installed and 
assembled / dismantled properly and correctly. 
Furthermore, it must be operated and serviced carefully. 

 

General Safety Instructions

 

► 

This device is electrically operated. Adhere strictly to the safety 

requirements relating to voltages applied to the device as described in the 
operating instructions! 

► 

Make sure that the electrical installation meets local or nationally applicable 

safety regulations. 

     

 Warning!

 

Failure to observe the information given in the warnings could result in  
Serious injury and/or major damage.  
Only personnel that have received appropriate training should operate this  
device or work in its immediate vicinity. The personnel must be fully familiar 
with all of the warnings and maintenance measures in these operating  
instructions. 
Correct transport, storage, and assembly / dismantling as well as careful  
operation and maintenance are essential in ensuring safe and reliable  
operation of this device. 

     

 Warning!

 

Any work that may have to be performed on the electrical installation should 
be performed by fully qualified technicians only.  

Safety Guidelines Environment

 

     

 Warning!

 

The device may only be operated in the listed ambient temperature range  
at the listed relative air humidity (non-condensing). 

► 

The installation location is to be selected so as to ensure compliance with  

the climatic limits listed in the Technical Data. 

 

Recycling Note 

 

 

After its use, this product has to be processed as electronic scrap and  

disposed of according to the prevailing waste disposal regulations of your 
community/district /country/state. 

 
 
Assembly 
 
1. Assemble cable with parts 

 

► 

Place parts on cable in correct order as shown: 

 

1.

 

Pressure screw

 

2.

 

Clamping cage

 

3.

 

Sealing ring 

 

4.

 

Connector body

 

 
 
 
2. Strip off cable 

 

► 

Strip off cable according to drawing:  

-

 

Length of cable jacket to be stripped: 

20 ± 1 mm 

-

 

Shorten wire for Pin 5: 

11 ± 1 mm 

-

 

Length of wires to be stripped: 

5 + 1 mm 

-

 

5x crimp wire end sleeves l = max. 6 mm according to DIN EN 46228-1 

 

Caution: Do not

 damage the individual wires.

  

 
 
 
 
 
 
 

3. Connect wires

 

 

► 

Move insulating tube over wire for Pin 5. 

► 

Insert core with wire end sleeve for Pin 5 into contact hole 

to the bottom and tighten contact screw M 2.5. 
Recommended torque: 30-40 Ncm. 

► 

Pull insulating tube over center contact. 

 
► 

Insert other cores with wire end sleeves into contact holes 

to the bottom and tighten contact screws M 2.5.

 

 

Recommended torque: 30-40 Ncm. 

 
 
 
 
 
 
 
 

4. Complete assembly 

► 

Screw connector body onto contact carrier assembly.  

Recommended torque: 45-55 Ncm. 

 

► 

Insert sealing ring and clamping cage into the connector body. 

 

► 

Screw the pressure screw to connector body. 

Recommended torque: 100-110 Ncm.

 

 

 

 
 
 
 
 
 

Cable socket 

Cable plug 

5-pol. 

4-pol. 

Cable socket 

Cable plug 

Отзывы: