Installation BAT867-R
Release 10 09/2021
31
2.3
Installing the antennas
The devices have 2 Reverse SMA connectors for connecting external
antennas.
Note:
When using 2 antennas type BAT-ANT-RSMA-2AGN-R, you must
align each antenna in another spatial direction (x-y) so that both antennas are
arranged at right angles to each other.
When mounting only 1 antenna, insert a terminating resistor into the unused
socket. You can obtain terminating resistors as accessory.
Note:
Device variants with the configuration characteristic value Z contain a
pre-mounted terminating resistor SMA to ANT2 for RSMA ANT connectors.
You will find information on setting the transmit power in chapter
the transmit power” on page 39
.
2.4
Connecting the terminal blocks
Note:
The supply voltage is connected to the device casing through
protective elements exclusively.
WARNING
ELECTRIC SHOCK
Before connecting the electrical wires,
always
verify that the requirements
listed are complied with.
See “Requirements for connecting electrical wires” on page 10.
See “Requirements for connecting the supply voltage” on page 11.
Never insert sharp objects (small screwdrivers, wires, etc.) into the
connection terminals for electric conductors, and do not touch the terminals.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
Содержание Hirschmann BAT867-R