Requirements for connecting the supply voltage
The supply voltage is connected to the device casing through protective
elements exclusively.
The following requirements apply without restrictions:
All
of the following requirements are complied with:
The supply voltage corresponds to the voltage specified on the type plate of the
device.
The power supply conforms to overvoltage category I or II.
The power supply has an easily accessible disconnecting device (for example a
switch or a plug). This disconnecting device is clearly identified. So in the case of an
emergency, it is clear which disconnecting device belongs to which power supply
cable.
The power supply cable is suitable for the voltage, the current and the physical load.
Hirschmann recommends a conductor cross section of 0.5 mm² to 0.75 mm² (AWG20
up to AWG18).
The cross-section of the ground conductor is the same size as or bigger than the
cross-section of the power supply cables.
The following requirements apply alternatively:
Alternative 1
The power supply complies with the requirements for a limited power
source (LPS) according to IEC 60950-1 or PS2 according to IEC/
EN 62368-1.
Alternative 2
Relevant for North America:
The power supply complies with the requirements according to
NEC Class 2.
Alternative 3
All
of the following requirements are complied with:
The power supply complies with the requirements for a safety extra-
low voltage (SELV) according to IEC 60950-1 or ES1 according to
IEC/EN 62368-1.
A back-up fuse suitable for DC voltage is located in the plus conductor
of the power supply.
The minus conductor is on ground potential. Otherwise, a back-up
fuse is also located in the minus conductor.
Regarding the properties of this back-up fuse:
See “Technical data” on page 44.
Table 2:
Requirements for connecting the supply voltage