18
K-Frame Release Notes, Version 10.6
IP Addresses and Single Control Surface Systems
IP Addresses and Single Control Surface Systems
A new Grass Valley system will operate on an isolated network with the default IP addresses
configured at the factory (except for 32 Crosspoint Remote Aux panels). However, if you
wish to integrate the system into an existing network, wish to use gateway
communications, or wish to add more control surface components, then the IP addresses
may need to be changed.
IP Addresses and Multiple Control Surfaces and Suites
If you plan to use multiple control surfaces (for example, more than one Control Panel or
more than one Menu Panel) with the same Video Processor frame, you must make sure the
IP addresses of the additional items are unique before connecting them to the network.
Using default IP addresses will cause network conflicts and unpredictable system
operation. See the
K-Frame Installation & Service Manual
for network configuration
information.
Reserved For Future Use
CAUTION: Do not connect any devices
configured with the following IP
addresses to a Karrera network.
Video Processor Frame Gigabit
Ethernet
192.168.0.172
PCU Panel (Kayenne) Reserved LAN
Port
192.168.0.174
Note:
Customer orders with multiple Control Panels will be pre-
configured to the listed IP addresses. However, if one of these additional
Control Panels is reset to factory defaults, it will be given the standard 1A
default 192.168.0.173 address.
K-Frame System Default IP Addresses
Device
IP Address