GUIDE TO INSTALLATION AND OPERATION
4
| HCO-3901
2 Installation
2.1 Installation in the Densité frame
The HCO-3901 and its associated rear connector rear panel must be mounted in a Densité-3 or Densité-3+ series
frame, or in a GV Node.
•
It is not necessary to switch off the frame’s power when installing or removing the card.
•
With a double-width rear panel installed, the HCO-3901 must be installed in the right-most of the two slots
covered by the panel in order to mate with the panel’s connectors.
•
If it is placed in the wrong slot, the front panel LED will flash red. Move the card to other slot for correct
operation. No damage will result to the card should this occur.
See the manual for your Densité frame for detailed instructions on installing cards and their associated rear panels.
2.2 Rear Connector Panels
There are three rear panels available for the HCO-3901. The table summarizes their features, and their layouts are
shown in the figure below.
HCO-3901-3DRP-R-EX
HCO-3901-3DRP-R
HCO-3901-3SRP-R
Single-slot-width panel
♦
Double-slot-width panel
♦
♦
Bypass Relay
♦
♦
♦
CONNECTORS
BNC BNC
DIN
Ref IN
♦
♦
♦
Ref IN loop out
♦
♦
GPI I/O
♦
♦
3G/HD/SD IN
1 and 2
♦
♦
♦
3
♦
♦
3G/HD/SD OUT
PGM 1
♦
♦
♦
PGM 2
(phase inverted)
♦
PVW 1A
(phase inverted)
♦
PVW 1
(1B on –EX rear)
♦
♦
♦
PVW 2A
(phase inverted)
♦
PVW 2
(2B on –EX rear)
♦
♦
PVW 3A
(phase inverted)
♦
PVW 3
(3B on –EX rear)
♦
♦