background image

12

Installation WLC

Release 04 07/2019

Power

This LED provides information on the operating state of the device. 

Fan

The Fan LED displays the status of the fan:

To avoid damage to the hardware, an acoustic signal complements this 
LED. If the fan blocks or the CPU temperature exceeds 60°, the device 
emits a pulsed acoustic signal.

COM

Connection status of the serial configuration interface:

WLAN

Provides information on the operational state of the device and the 
connected Access Points. The WLAN display shows the following:

Off

Device switched off

Green

Blinking

Self-test after power-up

Green

On 
(permanently)

Device operational

Red/green Blinking 

alternately

No configuration password set in the device

Red

Blinking

Time limit for online connections reached

Green

On 
(permanently)

CPU temperature OK

Orange

On 
(permanently)

CPU temperature > 55°

Red

Blinking

Hardware defect of the fan or CPU temperature > 60°, additional 
acoustic signal

Off

No login session

Green

On 
(permanently)

Serial configuration session logged on

Orange

Flickering

Data transmission during the configuration session

Red

On 
(permanently)

The BAT-Controller WLC is out of order, one of the following 
elements is missing:
- Root certificate
- Device certificate
- Current time

Red

Blinking

The device is operational but a connection to an active access 
point is missing.

Green

On 
(permanently)

At least one active access point connected and authenticated.

Содержание 942 034-001

Страница 1: ...Installation WLC Release 04 07 2019 Technical support https hirschmann support belden com User Manual Installation BAT Controller WLC...

Страница 2: ...rformance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the b...

Страница 3: ...2 1 Searching for and configuring the device 18 2 1 1 Configuration with LANconfig 18 2 1 2 Configuration with WEBconfig 19 2 1 3 Configuration via the serial interface 22 2 2 The Setup Wizards 22 2...

Страница 4: ...ing Use undamaged parts Internal fuses are triggered only in the case of a detected error in the device In case of damage or malfunction of the device turn off the supply voltage and return the device...

Страница 5: ...g fan The internal workings of the basic device are not for users Do not reach inside a switched on device because of the danger caused by high energy densities Warning When installing the device make...

Страница 6: ...precisely the prescribed safety requirements for the voltage connections in this document Non observance of these safety instructions can cause material damage and or injuries Only appropriately quali...

Страница 7: ...equipment designed for use within certain voltage limits In accordance with the above named EU directives the EU conformity declaration will be at the disposal of the relevant authorities at the foll...

Страница 8: ...he device creates and uses high frequencies and can also radiate these frequencies If it is not installed and used in accordance with this operating manual it can cause radio transmission interference...

Страница 9: ...Installation WLC Release 04 07 2019 9 Legend The symbols used in this manual have the following meanings Listing Work step Subheading...

Страница 10: ...nnector cable for the configuration interface 19 mounting brackets Product CD Printed Installation Guide Return form If anything is missing please take up immediate contact to your dealer or to the ad...

Страница 11: ...the LED lights up very briefly in the respective color and stays then clearly longer 10x longer switched off Inverse flashing means the opposite Here the LED lights permanently in the respective colo...

Страница 12: ...ently Device operational Red green Blinking alternately No configuration password set in the device Red Blinking Time limit for online connections reached Green On permanently CPU temperature OK Orang...

Страница 13: ...vice temperature Date and time CPU load Memory load Number of VPN tunnels Orange Blinking At least the BAT Controller WLC found one new access point for authentication Red Blinking The BAT Controller...

Страница 14: ...s Points If the WLAN LED constantly illuminates in red the display also shows the following information SNTP status SCEP status LEDs of the LAN interfaces ETH 1 to ETH 4 LAN connector status in the in...

Страница 15: ...ce 4 Reset 5 Power switch 6 Power connection COM Connector for the serial configuration cable ETH 1 to 4 Ethernet sockets 10 100 1000Base Tx for connection to the LAN The device supports 10 Mbps 100 M...

Страница 16: ...ly Pressing the button restarts the device no matter how long you press it Reset or boot standard setting A short pressure on the button restarts the device Pressing the button 5 to 10 seconds or long...

Страница 17: ...n cable for this connection Connect the configuration interface figure 2 position 1 to an available serial interface on the PC Supply power and switch on supply power to the device by using the power...

Страница 18: ...n computer You can do that for example via the command line with ipconfig renew by reactivating the network connection or by restarting the computer Then start the search in LANconfig again Note Poten...

Страница 19: ...select Set date time from the context menu As soon as the WLAN Controller has valid time information the generation of the certificates root and device certificate starts Once the necessary certificat...

Страница 20: ...ssign IP addresses netmask and DNS server to other computers in the LAN if these are set for automatic retrieval of IP addresses auto DHCP In this constellation you reach the device from each computer...

Страница 21: ...an IP address from the DHCP server in the LAN This IP address is initially unknown and accessing the device hangs on the name resolution If the LAN also has a DNS server for name resolution and this...

Страница 22: ...uration interface Now configure the device with LANconfig or a terminal program Note Enter the parameters separate via a command line interface when you use a terminal program The most convenient opti...

Страница 23: ...2 Setup wizards under WEBconfig When usingWEBconfig also continue with the configuration by starting the Setup Wizards for example for Internet connections coupling LANs or RAS To do this click the co...

Страница 24: ...amental to assign the correct addresses to the devices in the LAN Also these computers have to know the IP addresses of 2 central stations in the LAN Standard gateway receives the packets which are ad...

Страница 25: ...cting a USB printer and for future extensions Configuration Serial V 24 RS 232 outband interface with Mini DIN8 connector Power supply Internal power supply unit 110 230 V Housing Robust metal housing...

Страница 26: ...Line 1 CTS 2 RTS 3 RxD 4 RI 5 TxD 6 DSR 7 DCD 8 DTR U GND Table 2 8 pin Mini DIN socket Name Order number BAT Controller WLC25 942 034 001 BAT Controller WLC50 942 034 002 BAT Controller WLC100 942 03...

Страница 27: ...mpetence Center is ahead of its competitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through network...

Страница 28: ......

Отзывы: