Release 04 07/2019

Power switch

Switch for detaching the device from the power supply.

Note: 

For an entire detachment from the power supply please unplug the 

power connection.

Power connection

Connector for the IEC cable for power supply unit. 

Reset button functions

The reset button offers 2 functions, which are called by pressing the 
button for different lengths of time. 'Boot'  restarts the device and 'reset' 
sets the device to the factory settings.
Pressing the button shortly restarts the device. Pressing the button 5 to 
10 seconds sets the configuration to the factory settings. The LEDs on the 
device light up continuously. Once you release the switch the device 
reboots with the restored factory settings.
Some devices suit only for an installation in free accessible areas. The 
configuration is deleted by mistake, if a co-worker presses the reset 
button too long. Define the behavior of the reset button with a setting in 
WEBconfig (LCOS-Menübaum / Setup / Config):

Ignore: The button shows no response to pressure.

Boot only: Pressing the button restarts the device, no matter how long 
you press it. 

Reset-or-boot (standard setting): A short pressure on the button 
restarts the device. Pressing the button 5 to 10 seconds or longer 
reboots the device and resets the configuration to its factory settings. 
The LEDs on the device light up continuously. 

Once you release the switch the device reboots with the restored factory 
settings.

Note: 

A reset causes the device to start with the default factory settings, 

any previous settings are lost. Any access points managed by this WLAN 
Controller lose their configuration, depending on the settings of the 
standalone operation. The standalone operation is described in the user 
manual.

Note: 

With the settings 'Ignore' or 'Boot only', you lock the device for being 

reset to the factory settings. If you lose the password for a device with this 
setting, there is no way to access the device. In this case use the serial 
communications interface to upload a new firmware version to the device. 
This action resets the device to its factory settings, which results in the 
deletion of the former configuration. Further information and help on the 
firmware upload via the serial communications interface is available in the 
Reference Manual.

Содержание 942 034-001

Страница 1: ...Installation WLC Release 04 07 2019 Technical support https hirschmann support belden com User Manual Installation BAT Controller WLC...

Страница 2: ...rformance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the b...

Страница 3: ...2 1 Searching for and configuring the device 18 2 1 1 Configuration with LANconfig 18 2 1 2 Configuration with WEBconfig 19 2 1 3 Configuration via the serial interface 22 2 2 The Setup Wizards 22 2...

Страница 4: ...ing Use undamaged parts Internal fuses are triggered only in the case of a detected error in the device In case of damage or malfunction of the device turn off the supply voltage and return the device...

Страница 5: ...g fan The internal workings of the basic device are not for users Do not reach inside a switched on device because of the danger caused by high energy densities Warning When installing the device make...

Страница 6: ...precisely the prescribed safety requirements for the voltage connections in this document Non observance of these safety instructions can cause material damage and or injuries Only appropriately quali...

Страница 7: ...equipment designed for use within certain voltage limits In accordance with the above named EU directives the EU conformity declaration will be at the disposal of the relevant authorities at the foll...

Страница 8: ...he device creates and uses high frequencies and can also radiate these frequencies If it is not installed and used in accordance with this operating manual it can cause radio transmission interference...

Страница 9: ...Installation WLC Release 04 07 2019 9 Legend The symbols used in this manual have the following meanings Listing Work step Subheading...

Страница 10: ...nnector cable for the configuration interface 19 mounting brackets Product CD Printed Installation Guide Return form If anything is missing please take up immediate contact to your dealer or to the ad...

Страница 11: ...the LED lights up very briefly in the respective color and stays then clearly longer 10x longer switched off Inverse flashing means the opposite Here the LED lights permanently in the respective colo...

Страница 12: ...ently Device operational Red green Blinking alternately No configuration password set in the device Red Blinking Time limit for online connections reached Green On permanently CPU temperature OK Orang...

Страница 13: ...vice temperature Date and time CPU load Memory load Number of VPN tunnels Orange Blinking At least the BAT Controller WLC found one new access point for authentication Red Blinking The BAT Controller...

Страница 14: ...s Points If the WLAN LED constantly illuminates in red the display also shows the following information SNTP status SCEP status LEDs of the LAN interfaces ETH 1 to ETH 4 LAN connector status in the in...

Страница 15: ...ce 4 Reset 5 Power switch 6 Power connection COM Connector for the serial configuration cable ETH 1 to 4 Ethernet sockets 10 100 1000Base Tx for connection to the LAN The device supports 10 Mbps 100 M...

Страница 16: ...ly Pressing the button restarts the device no matter how long you press it Reset or boot standard setting A short pressure on the button restarts the device Pressing the button 5 to 10 seconds or long...

Страница 17: ...n cable for this connection Connect the configuration interface figure 2 position 1 to an available serial interface on the PC Supply power and switch on supply power to the device by using the power...

Страница 18: ...n computer You can do that for example via the command line with ipconfig renew by reactivating the network connection or by restarting the computer Then start the search in LANconfig again Note Poten...

Страница 19: ...select Set date time from the context menu As soon as the WLAN Controller has valid time information the generation of the certificates root and device certificate starts Once the necessary certificat...

Страница 20: ...ssign IP addresses netmask and DNS server to other computers in the LAN if these are set for automatic retrieval of IP addresses auto DHCP In this constellation you reach the device from each computer...

Страница 21: ...an IP address from the DHCP server in the LAN This IP address is initially unknown and accessing the device hangs on the name resolution If the LAN also has a DNS server for name resolution and this...

Страница 22: ...uration interface Now configure the device with LANconfig or a terminal program Note Enter the parameters separate via a command line interface when you use a terminal program The most convenient opti...

Страница 23: ...2 Setup wizards under WEBconfig When usingWEBconfig also continue with the configuration by starting the Setup Wizards for example for Internet connections coupling LANs or RAS To do this click the co...

Страница 24: ...amental to assign the correct addresses to the devices in the LAN Also these computers have to know the IP addresses of 2 central stations in the LAN Standard gateway receives the packets which are ad...

Страница 25: ...cting a USB printer and for future extensions Configuration Serial V 24 RS 232 outband interface with Mini DIN8 connector Power supply Internal power supply unit 110 230 V Housing Robust metal housing...

Страница 26: ...Line 1 CTS 2 RTS 3 RxD 4 RI 5 TxD 6 DSR 7 DCD 8 DTR U GND Table 2 8 pin Mini DIN socket Name Order number BAT Controller WLC25 942 034 001 BAT Controller WLC50 942 034 002 BAT Controller WLC100 942 03...

Страница 27: ...mpetence Center is ahead of its competitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through network...

Страница 28: ......