30
Installation MACH104-PoEP
Release 10 09/2019
Every
time you connect the electrical conductors, make sure that the
following requirements are met:
The electrical wires are voltage-free.
The connected voltage is limited by a current limitation device or a fuse.
Observe the electrical threshold values for the signal contact.
See “General technical data” on page 38.
Remove the terminal connector from the device.
Connect the signal contact lines with the terminal block connections.
Mount the terminal block for the signal contact on the front of the device
using the screw lock. Check whether the terminal block is correctly
plugged and screwed on.
You find the prescribed tightening torque in chapter:
“General technical data” on page 38
2.5
Installing the device and grounding
The device can be mounted on a flat surface, in a 19" standard switch
cabinet, or on the wall.
2.5.1
Selecting the assembly location
Select the assembly location according to the safety guidelines
(see on
.
When selecting the assembly location, also make sure the following
requirements are met:
The assembly location can be accessed for maintenance and repair work.
The LED display elements are clearly visible.
Twisted pair cables are at a sufficient distance from potential sources of
electrical interference, such as power supply cables.
The device has a separate power source with a ground connection. The
power supply can be interrupted by means of a separate isolator or power
switch. We recommend using overvoltage protection for all devices.
2.5.2
Mounting on a flat surface
Before operating the device on a flat surface, such as a table, stick the
supplied casing feet onto the bottom of the device, with approx. 0.8 in (2 cm)
of space from the corners.
If necessary, remove any dirt from the bottom of the device where you
want to place the stick-on feet.
Remove the protective foil from the adhesive surface of a casing foot and
attach the casing foot on the device.