It is important that the cabling to and from the multiviewer is correctly labeled and routed. This
will simplify the work required if the installation needs to be changed or added to at a future
date.
Sirius Router Power Requirements
Before adding an MV-800 to a Sirius 800 router frame, check that the power supplies fitted to
the router frame can supply sufficient power to the router and MV-800. See the Sirius 800 User
Manual for router power requirements and contact Grass Valley Support for advice.
CAUTION
• Cables connected to the MV-800 Integrated Multiviewer must be
fitted with adequate vertical and horizontal strain relief to avoid
twisting of the rear panels causing damage to the MV-800 rear
connectors and loss of electrical/signal connection to the
multiviewer or monitor displays.
• Cables connected to the MV-800 Integrated Multiviewer should
be routed so they do not cover any of the router frame fan
exhausts because any obstruction can restrict cooling airflow
through the router.