background image

    Beko 2010 LED 8 kg Condanser 

     Tumble Dryer Service Handbook 

 

10

 
 
Dryer Principals: 

 

The air heated by the heaters, is directed to the drum and  gets moisture of the laundry. 
After crossing from the filters, the air pass through the condenser, and condenses. 
Then the air is heated again, this circulation continues until the drying process finished. 
Condensing occurs by cooling the air. To achieve that, a secondary fan circulates the air in the 
condenser. Because of the temperature difference between cooling air and heated air, 
condensing process accomplishes. 
 
The condensed water is directed to the water tank by the pump for tank up version. 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  Heater 

  Process Fan 

  Cooling Fan 

  Condensed Water 

  Condenser 

 
 
 
 
 
 
 
 
 
 

Содержание DCU 8230

Страница 1: ...mble Dryer Service Handbook 1 INDEX 1 Technical Specifications 2 Components and Dryer Principals 3 Control System 4 Service test program 5 Fault algorithms 6 Wiring schematics 7 Exploded views 8 Spare part list 9 Demounting the dryer ...

Страница 2: ...Beko 2010 LED 8 kg Condanser Tumble Dryer Service Handbook 2 ...

Страница 3: ...ogram heater off 1 2 Dimensions 1 2 1 Height mm 846 1 2 2 Depth mm 598 1 2 3 Width mm 595 1 3 Package 1 3 1 Material PE bag Shrink pack 1 3 2 Supporter Polystrofoam Wood 1 3 3 Dimensions Height mm 880 Depth mm 660 Width mm 650 1 4 Weight 1 4 1 Unpacked kg 38 1 4 2 Packed kg 40 1 5 Working Condition 1 5 1 Temperautre Min room temperature 5 C Max room temperature 35 C 1 5 2 Humudity 95 RH 1 6 Electr...

Страница 4: ...n capacitor 9 mF 5 1 9 Heater 1 9 1 Type Open wire spiral heating element 1 9 2 Nominal Power Voltage W 230Vac 1600 700 2300 5 1 9 3 Resistance ohm 1600 W 1 level power 32 41 ohm 5 700 W 2 level power 73 67 ohm 5 Warning NTC regulating thermistor is damaged change the heating element completely Also check whether the motor or the fan is blocked or the belt is broken 1 9 4 Manual resetting thermost...

Страница 5: ...l resetting thermostat is checked from the terminals while heater is on the dryer If manual resetting thermostat is open curcuit the button is up and the heater does not work If the button is up position push the button down and measure the thermostat and be sure that it is short circuit ...

Страница 6: ...or opening mm 395x320 1 12 5 Proces air flow m3 h 190 1 12 6 Maximum loading Capacity Cotton kg 8 Delicate Synthetic kg 4 1 13 Control System Specifications 1 13 1 On off Button 250 V 16 4 A 1 13 2 Door Switch 250 V 3 1 A veya 16 4 A 1 13 3 Suppression Filter 0 15 uF X1 1Mohm 2x0 027uF Y2 1 13 4 Program Timer Electronic Control Card 220 240V 50 Hz 1 14 Pump 1 14 1 Number of turns 2x3250 1 14 2 Wir...

Страница 7: ...ectronic controlled dryers one is located after the door filter in suction canal other is located in the heater As the temperature of the surrounding of NTC increases its resistance decreases At fixed temperature NTC will always have a specified resistance within the tolerance With the aid of this principle operates until the desired temperature is reached In this way the selected program complete...

Страница 8: ...nical thermostat operates only Locked tumble Locked rotor Broken fan Filter and condenser is full conditions Warning When NTC is broken down the heater is changed by the new heater If thermostat is open curcuit the same heater will be used by pressing the button on thermostat Door Lock Locking and unlocking mechanism of the door lock used in the dryer is a mechanical type of the door lock When the...

Страница 9: ... 2 poles asenkron motor Motor turns 2750 prm ans has a 9 uF capacitor Asenkron motor is controled by two Control panel two relays one of them for direction other one is for energy that placed in control Auxiliary Winding Common Run Capasitor Auxiliary Winding Main Winding Common Main Winding ...

Страница 10: ...nses Then the air is heated again this circulation continues until the drying process finished Condensing occurs by cooling the air To achieve that a secondary fan circulates the air in the condenser Because of the temperature difference between cooling air and heated air condensing process accomplishes The condensed water is directed to the water tank by the pump for tank up version Heater Proces...

Страница 11: ...Beko 2010 LED 8 kg Condanser Tumble Dryer Service Handbook 11 3 Control System ...

Страница 12: ...Beko 2010 LED 8 kg Condanser Tumble Dryer Service Handbook 12 ...

Страница 13: ...Beko 2010 LED 8 kg Condanser Tumble Dryer Service Handbook 13 ...

Страница 14: ...Beko 2010 LED 8 kg Condanser Tumble Dryer Service Handbook 14 ...

Страница 15: ...Beko 2010 LED 8 kg Condanser Tumble Dryer Service Handbook 15 ...

Страница 16: ...4 The start stop cancel button is pushed The ready to iron led goes off and the ready to wear dry led is activated Motor turns clockwise After 3 seconds buzzer cancel led blinks Till the end of 3 second the buzzer cancel led won t blink even if the start button is pushed Step 5 The start stop cancel button is pushed The ready to wear led goes off and the end led is activated Motor turns clockwise ...

Страница 17: ...he drying led goes off and the ready to iron led is activated Motor turns clockwise The 1600W heater is on After 3 seconds buzzer cancel led blinks Till the end of 3 second the buzzer cancel led won t blink even if the start button is pushed Step 8 The start stop cancel button is pushed Turn back to the step 1 ...

Страница 18: ...e electrical connections Connect the power supply YES NO Check the electricity on the main control card YES Change the main card NO Check the on off switch connections Check the connections NO Check the interfere filter YES NO Check the connections YES Check the main control card and change it if necessary ...

Страница 19: ...rying time is too long Check the heaters relays Reset the heater Is the heater thermic NC on Check the software change the main card Change the heater Check the heater connections YES NO YES NO YES NO YES Is the heater thermic NC NTC correct NC Normal closed short circuit NO Normal open short circuit ...

Страница 20: ... not be set Are the values on the program selector potentiometer correct Potentiometer YES NO Each turn of rotary knob there should be 1Kohm increase If it is not change the rotary Is the Rotary main card connection correct NO YES Change main card Change the the connections ...

Страница 21: ...um is not rotating Is V belt on Fix the V belt NO Are the motor relays running YES Check the software change the main control card NO Are motor winding resistance are correct Motor heating problem wait till the motor thermic is short circuit Change the motor YES NO YES ...

Страница 22: ...ryer Service Handbook 22 Program doesn t progress although the tank is empty Is the overflow switch is broken YES NO Fix or change the overflow switch Is the overflow switch is broken NO YES Check the pump Fix or change the overflow switch ...

Страница 23: ...Beko 2010 LED 8 kg Condanser Tumble Dryer Service Handbook 23 6 Wiring Schematics Beko 2010 Condenser LED Wiring Schematics ...

Страница 24: ...Beko 2010 LED 8 kg Condanser Tumble Dryer Service Handbook 24 Beko 2010 Condenser Cable Schematics ...

Страница 25: ...Beko 2010 LED 8 kg Condanser Tumble Dryer Service Handbook 25 7 Expoled Views 8 Spare Parts List 9 Demounting ...

Отзывы: