Beko 2010 LED 8 kg Condanser
Tumble Dryer Service Handbook
19
Degree of drying can’t be
reached or drying time is too
long
Check the
heaters relays
Reset the heater
Is the heater
thermic (NC)
on?
Check the software,change
the main card
Change the heater
Check the heater
connections
YES
NO
YES
NO
YES
NO
YES
Is the heater
thermic (NC)/NTC
correct?
NC = Normal closed short circuit
NO = Normal open short circuit
Содержание DCU 8230