9.4 Replace the float drain
For float drain replacement to be carried out, the following prerequisites must be fulfilled and the preparatory tasks
must have been completed.
Prerequisites
Tools
Material
Protective equipment
• Screwdriver - cross-head
size 2.5 mm
•
New float drain with adapter
enclosed
•
Protective gloves (fluid-
resistant)
•
Safety goggles with side shields
•
Hearing protection
•
Respiratory protection,
protection class FFP 3
•
Safety footwear
Preparation of installation
1.
Open the bypass pipe if available
Figure
Description
1.
1.
1. Close the shut-off valves upstream and downstream of
the filter or the respective system section
2.
2.
Set the knurled screw on the float drain anti-clockwise
(left-hand thread) from >>
Automatic discharge
<< to
>>
Mechanical open
<<
Automatic discharge
Mechanically open
CLEARPOINT
®
3
eco
coalescing filter
Installation and operation manual
32 | 56