5. Technical data
5.1 Filter performance data
CLEARPOINT
®
3
eco
S040
S050
S055
S075
M010
M012
M015
Connection [inches]
3/8
1/2
1/2
3/4
1
1
1 1/2
Volume flow at 7 bar(g)
energy-optimised [m³/h]
*1
35
65
100
150
200
250
320
Differential
pressure [mbar]
(wet saturated)
CX
Ø
50
FX
80
115
150
105
120
165
80
SX
100
125
170
120
135
180
100
Volume flow at 7 bar(g)
performance-oriented [m³/h]
*1
46
85
130
195
260
325
415
Differential
pressure [mbar]
(wet saturated)
CX
Ø
70
FX
105
160
230
150
180
230
110
SX
125
170
255
175
200
260
130
Category according to
PED 2014/68/EU
-
-
-
-
-
-
-
Min./max. operating pressure
[bar(g)]
0 ... 16
Min./max. operating temperature
[°C]
+2 ... +60
Load test according to AD2000
10000 load changes
≙
pressure difference ≥3.2 bar at 16 bar(g)
Medium
Compressed gases of fluid group 2 according to PED 2014/68/EU
free of aggressive and corrosive components
Weight [kg]
0.75
0.85
1.2
1.7
2.1
2.2
4.1
Volume [l]
0.25
0.31
0.42
0.87
1.12
1.26
2.52
*1
Volume flow at 7 bar(g) referring to +20 °C and 1 bar(abs)
Installation and operation manual
CLEARPOINT
®
3
eco
coalescing filter
21 | 56