Free match split type air conditioner / Installation Manual
11.1 Automatic wiring/piping correction function
More recent models now feature automatic correction of wiring/piping errors. Press the "check switch"
on the outdoor unit PCB board for 5 seconds until the LED displays "CE”, indicating that this function is
working, Approximately 5-10 minutes after the switch is pressed, the "CE" disappears, meaning that
the wiring/piping error is corrected and all wiring/piping is properly connected.
Check switch
LED display
B
A
B
A
B
A
B
A
B
A
B
A
Indoor unit B
Indoor unit B
Outdoor unit
Outdoor unit
Correct wiring
Incorrect wiring
Incorrect wiring
Terminal
block
Terminal
block
Liquid/
Gas pipe
Liquid/
Gas pipe
Indoor unit A
Indoor unit A
11
Function of automatic wiring/piping correction