28 / 116 EN
Split Type Air Conditioner / User Manual
4.3 Outdoor Unit Installation
Install the unit by following local codes and
regulations , there may be differ slightly between
different regions.
ev
o
ba
)
ni
42
(
mc
06
60cm (24in)
on righ
t
30cm (12in)
on left
200cm (79in)
in fron
t
30cm (12in)
from back wall
30cm (12in) on left
60cm (24in) on right
60cm (24in) a
bove
30cm (12in)
from back wall
200cm (79in) in front
4.3.1 Installation Instructions – Outdoor
unit
Step 1: Select installation location
Before installing the outdoor unit, you must
choose an appropriate location. The following
are standards that will help you choose an
appropriate location for the unit.
Proper installation locations meet the
following standards:
•
Meets all spatial requirements shown in Instal-
lation Space Requirements above.
•
Good air circulation and ventilation
•
Firm and solid—the location can support the
unit and will not vibrate
•
Noise from the unit will not disturb others
•
Protected from prolonged periods of direct
sunlight or rain
•
Where snowfall is anticipated, raise the unit
above the base pad to prevent ice buildup and
coil damage. Mount the unit high enough to be
above the average accumulated area snowfall.
The minimum height must be 18 inches.
DO NOT install unit in the following
locations:
•
Near an obstacle that will block air inlets and
outlets
•
Near a public street, crowded areas, or where
noise from the unit will disturb others
•
Near animals or plants that will be harmed by
hot air discharge
•
Near any source of combustible gas
•
In a location that is exposed to large amounts
of dust.
•
In a location exposed to a excessive amounts
of salty air.
C
If the unit is exposed to heavy
wind: Install unit so that air
outlet fan is at a 90° angle
to the direction of the wind. If
needed, build a barrier in front
of the unit to protect it from
extremely heavy winds. See
Figures below.
Strong wind
Wind baffle
Strong
wind
Strong wind
C
If the unit is frequently exposed
to heavy rain or snow:
Build a shelter above the unit to
protect it from the rain or snow.
Be careful not to obstruct air
flow around the unit.
If the unit is frequently exposed
to salty air (seaside):
Use outdoor unit that is specially
designed to resist corrosion.
4 Installation
Содержание BIHPR 090
Страница 2: ...ENGLISH 3 55 ITALIANO 56 116 CONTENTS V2111001 AF UM ...
Страница 114: ......
Страница 115: ......
Страница 116: ...Arçelik A Ş Karaağaç Caddesi No 2 6 34445 Sütlüce İstanbul Türkiye www beko com ...