2.6. Technical data
General data
BM 8
BM 9
Min./max. storage/transport temperature
+1 … +60 °C
Min./max media/ambient temperature
+1 … +60 °C
Min./max operating overpressure
0.5 … 10 bar
0.5 … 4 bar
Condensate inlet
Fl. C50 x 60.3 DIN 1092-1
Condensate discharge
G1
G2
Venting connection
G3/4
Manual condensate drain
G3/4
Condensate
Oil-contaminated, oil-free condensate
Weight
28.0 kg (empty)
38.0 kg (empty)
Container volume
19.5 l
44 l
Drain volume per cycle
15 l
36 l
Materials
Housing: Stainless steel (material no. 1.4541)
Valve: Brass
Electrical data
BM 8
BM 9
Operating voltage
230 / 200 / 110 / 100 / 48 / 24 VAC
±10 %; 50 … 60 Hz; 24 VDC
(see type plate)
Power consumption
< 10 VA
Recommended cable cross section
ø 5.8 … 11 mm; 3 x 0.75 mm²
Protection (medium time lag)
0.5 A
Alarm relay: Contact load
P < 125 W / VA; I = 0.1 … 0.5 A
U < 250 VAC; U > 12 VDC
2.6.1. Performance data
BM 8
BM 9
Operating
pressure
Annual nominal
capacity
Maximal capacity
(short period)
Annual nominal
capacity
Maximal capacity
(short period)
[bar]
[m
3
/a]
[l/h]
[m
3
/a]
[l/h]
0.5
9,360
1,400
24,000
3,600
1.0
10,700
2,250
29,200
6,130
2.0
11,100
3,330
29,600
8,880
4.0
11,400
4,800
30,000
12,600
6.0
12,700
5,580
--
--
8.0
13,700
6,000
--
--
10.0
14,400
6,300
--
--
Содержание BEKOMAT 8
Страница 1: ...BEKOMAT 8 BEKOMAT 9 EN English 01 3048 Condensate drain Installation and operation manual ...
Страница 2: ...Installation and operation manual EN 2 BEKOMAT 8 9 ...
Страница 24: ...Installation and operation manual EN 24 BEKOMAT 8 9 8 Declaration of Conformity ...
Страница 26: ...Installation and operation manual EN 26 BEKOMAT 8 9 ...
Страница 27: ...EN Installation and operation manual BEKOMAT 8 9 27 ...