Installation and Operation Manual
BEKOKAT
®
V01 / 11-043
69 / 88
6.2
Reactor temperature> + 200 °C
Malfunction image
The reactor temperature rises during operation above T> + 200 °C.
Close valves V1 / V2. The compressed air supply is interrupted.
As soon as the valves close, the potential-free alarm contact is activated, signalling the fault
by means of an external display (warning signal, indicator light, etc.). This connection option
should be used.
Cause
Measure
The system must be shut down and checked in all cases if the reactor temperature is
exceeded.
The air flow through the reactor was
interrupted for a long time.
Check that the compressor regularly
supplies compressed air to the reactor.
Establish compressed air supply.
The amount of oil entering the
BEKOKAT
®
is too large.
Check oil separator of compressor.
In addition to the automatic closing of the valves at the inlet and outlet, in this case the manual
shut - off valves must also be closed before and after the system.
DANGER Commissioning
Commissioning of the BEKOKAT
®
is only permitted after inspection and
approval by authorised skilled technical personnel.