Installation and Operation Manual
BEKOKAT
®
V01 / 11-043
15 / 88
1.4
Special notes for pressurised equipment according to
Pressure Directive 2014/68/EU
Proper utilisation of the
BEKOKAT
®
is a fundamental prerequisite for safe operation. The
owner and/or operator must therefore always proceed as follows:
The
BEKOKAT
®
must only be operated within the pressure and temperature limits
specified by the manufacturer on the rating plate.
The
BEKOKAT
®
may only be used for fluid group 2 medium according to PED 2014/68
/ EU, i.e. with a medium free of aggressive, corrosive, toxic, flammable and oxidizing
components.
The housing and frame of the systems must not be welded.
The
BEKOKAT
®
must neither be operated in insufficiently ventilated rooms nor near
heat sources or flammable, hazardous materials or substances.
To prevent breakages caused by material fatigue, the
BEKOKAT
®
must be protected
against vibration during operation.
The maximum permissible operating pressure specified on the manufacturer type plate
must not be exceeded under any circumstances. It is the responsibility of the operating
company to install suitable safety and control devices to prevent excessive pressure.
The documentation shipped with the
BEKOKAT
®
(manual, operating instructions,
Declaration of Conformity, etc.) must be kept in good condition for future viewing and
reference.
No objects may be attached or placed on the
BEKOKAT
®
and connecting cables.
Never carry out welding work on the pressure vessel or alter it in any way!
Only install the plant in frost-free rooms.
The operation of the system is permitted only with completely closed and intact
housings and panels. The operation of the system with a damaged housing/casing is
prohibited.
The compressed air system in which the
BEKOKAT
®
is integrated must have pressure
limiting devices.
WARNING
Unauthorised interference