22 / 184 EN
Split Type Air Conditioner / User Manual
4 Installation
4.2 Installation Instructions –
Indoor unit
4.2.1 Prior to installation
Before installing the indoor unit, refer to the label
on the product box to make sure that the model
number of the indoor unit matches the model
number of the outdoor unit.
Step 1: Select installation location Before installing
the indoor unit, you must choose an appropriate
location. The following are standards that will help
you choose an appropriate location for the unit.
Proper installation locations meet the
following standards:
•
Good air circulation
•
Convenient drainage
•
Noise from the unit will not disturb other people
•
Firm and solid—the location will not vibrate
•
Strong enough to support the weight of the unit
•
A location at least one meter from all other
electrical devices (e.g., TV, radio, computer)
DO NOT install unit in the following locations:
•
Near any source of heat, steam, or combustible
gas
•
Near flammable items such as curtains or
clothing
•
Near any obstacle that might block air circulation
•
Near the doorway
•
In a location subject to direct sunlight
C
If there is no fixed refrigerant
piping: While choosing a
location, be aware that you
should leave ample room for
a wall hole (see Drill wall hole
for connective piping step) for
the signal cable and refrigerant
piping that connect the indoor
and outdoor units. The default
position for all piping is the right
side of the indoor unit (while
facing the unit). However, the
unit can accommodate piping to
both the left and right.
Refer to the following diagram to ensure
proper distance from walls and ceiling:
12cm (4.72in)
or more
2.3m (90.55in) or more
12cm (4.72in)
or more
15cm (5.9in) or more
15cm (5.9in) or more
2.3m (90.55in) or more
12cm (4.72in)
or more
12cm (4.72in)
or more
Step 2: Attach mounting plate to wall
The mounting plate is the device on which you will
mount the indoor unit.
•
Remove the screw that attaches the mounting
plate to the back of the indoor unit.
•
Secure the mounting plate to the wall with the
screws provided. Make sure that mounting plate
is flat against the wall.
Содержание BEEPI 090
Страница 2: ...ENGLISH 3 58 ROMÂNĂ 59 116 УКРАЇНСЬКОЮ 117 184 CONTENTS V2110002 AB UM ...
Страница 182: ......
Страница 183: ......
Страница 184: ...Arçelik A Ş Karaağaç Caddesi No 2 6 34445 Sütlüce İstanbul Türkiye www beko com ...