BLG15 C7S SERVICE MANUAL
Sensitivity: Public
6.20
Lower Counterweight Installation/Removal
Front wall is removed.
Lower Counterweight Retaining Bolts are removed. (During the installation of upper
and lower counterweights, torque value must be 1900 Ncm (-200 tolerance).
Picture 6.109 Lower Counterweight Installation/Removal
6.21
Drain Pump Installation/Removal
Remove the upper table.
Panel is removed.
Front wall is removed.
Screws on the body are removed. Picture 6.122.
Clamp at the pump inlet of the discharge hose is pulled backwards.
Remove cable.
Pump is removed.
Picture 6.110 Drain pump Installation/Removal