1.  DESCRIPTION

The BA444DF-P fieldbus indicator is an intrinsically
safe,  PROFIBUS  PA  instrument,  that  may  be
configured  as  a  fieldbus  node  or  as  a  fieldbus
listener. It can display up to eight fieldbus process
variables  on  a  five  digit  LCD  and  a  31  segment
analogue  bargraph.      The  instrument  is  bus
powered so no additional power supply is required
and  has  PROFIBUS  PA  User  Organisation
approval, certificate Z01505. 

Fieldbus node configuration may be performed by
either a User PRM data download or by a DPV1
configurator,  and  if  required,  the  instrument
address may be entered via the front panel push
buttons.  

When  configured  as  a  fieldbus  listener,  the
BA444DF-P is not visible to the fieldbus host and
can only be configured using the push buttons on
the front of the instrument.

Housed in a robust IP66 glass reinforced polyester
(GRP) enclosure with a toughened glass window,
the  BA444DF-P  is  surface  mounting,  or  may  be
pipe mounted using one of the accessory kits.  

The instrument has been certified intrinsically safe
by  European  Notified  Body  Intertek  Testing  and
Certification Ltd (ITS) for use in explosive gas and
combustible  dust  atmospheres.      ATEX  dust
certification is an option – see Appendix 1.

For use in the USA and Canada, the BA444DF-P is
available with intrinsic safety and nonincendive FM
and cFM Approval – see Appendix 2. 

For  international  applications,  all  versions  of  the
BA444DF-P PROFIBUS PA indicator have  IECEx
intrinsic  safety  approval  allowing  installation  in
explosive  gas  atmospheres.      IECEx  dust
certification  is  available  as  an  option  –  see
Appendix 3.

The instrument’s communication protocol is shown
on a label inside the terminal cover.  The ‘-P’ order
code  suffix  also  indicates  the  protocol  but  is  not
shown  on  the  instrument  certification  label.
There  is  an  alternative  version  of  the  fieldbus
display,  order  code  BA444DF-P  for  use  on
FOUNDATION™ fieldbus networks.

1.1

  

Documentation

This  instruction  manual  describes  ATEX  system
design  and  installation  of  the  BA444DF-P
PROFIBUS PA indicator.

System design information for non-ATEX and dust
approvals is shown in appendices to this manual.

2.  OPERATION

The BA444DF-P indicator can display up to eight
pre-configured  PROFIBUS  PA  process  variables
designated in-1 to in-8.   The operator can select
which variable is displayed using the 

 or 

 push

buttons which scroll the display through the eight
inputs.      A numeric  annunciator  on  the  left  hand
side of the display shows which of the eight inputs
is currently being displayed.

2.1  Error messages

‘no ConF’

No inputs have been 
configured or are enabled.

‘no dAtA’

No data is being received 
with the current configuration.

3.  INTRINSIC SAFETY CERTIFICATION

3.1 ATEX certificate

The BA444DF-P has been issued with an EC-Type
Examination  Certificate  ITS06ATEX25313X  by
Notified Body Intertek Testing and Certification Ltd
(ITS)  confirming  compliance  with  harmonised
European  standards.    The  BA444DF-P  fieldbus
indicator  has  Ex  ia  FISCO  and  entity  parameter
certification plus Ex ic entity parameter approval for
use in Zone 2 with higher supply voltages.  

The  EC-Type  Examination  certificate  has  been
used  to  confirm  compliance  with  the  European
ATEX Directive 94/9/EC.  The  BA444DF-P carries
the Community Mark and, subject to local codes of
practice, may be installed in any of the European
Economic  Area  (EEA)  member  countries.    ATEX
certificates are also acceptable for installations in
Switzerland. 

This  manual  describes  ATEX  installations  in
explosive  gas  atmospheres  which  conform  with
EN

 

60079:14

 

Electrical  installation  design,

selection and erection.

    When designing systems

for  installation  outside  the  UK,  the  local  Code  of
Practice should be consulted.  

For  use  in  the  presence  of  combustible  dust,
please refer to Appendix 1.

3

Содержание PROFIBUS PA BA444DF-P

Страница 1: ...Issue 5 16th December 2015 BA444DF P PROFIBUS PA Intrinsically safe Field mounting 8 variable Fieldbus Indicator Issue 5...

Страница 2: ...ions 6 4 Description of listener menu functions 6 4 1 Scan fieldbus segment 6 4 2 List configured input parameters 6 4 3 Enter address display parameters 6 4 4 Enable selected input 6 4 5 Enter source...

Страница 3: ...There is an alternative version of the fieldbus display order code BA444DF P for use on FOUNDATION fieldbus networks 1 1 Documentation This instruction manual describes ATEX system design and install...

Страница 4: ...ure classification of T1 450oC T2 300oC T3 200oC T4 135oC At an ambient temperature between 40 and 70o C Note the guaranteed operating temperature range of the BA444DF P Fieldbus Indicator is 20 to 70...

Страница 5: ...t should be equal to or less than Uo 22V dc Io 250mA dc Po 1 2W The segment can provide an additional 13mA to power the Fieldbus Indicator The equivalent capacitance Ci of the BA444DF P Fieldbus Indic...

Страница 6: ...entries 5 2 Installation Procedure Fig 2 illustrates the instrument installation procedure a Remove the instrument terminal cover by unscrewing the two captive A screws b Mount the instrument on a fl...

Страница 7: ...Fig 3 Dimensions and terminal connections 7...

Страница 8: ...ng the or button When set as required operating the P button will transfer control to the next digit that may be adjusted in the same way When all digits are set as required operating the E button wil...

Страница 9: ...ed by the BA444DF P listener are not known In the SCAn function pressing the P button causes the BA444DF P listener to search the fieldbus segment to which it is connected for all data sources The hex...

Страница 10: ...rs Sub menu which allows known fieldbus device addresses to be entered and all display parameters adjusted for each of the eight fieldbus listener inputs See section 6 4 3 Enb Enable selected input En...

Страница 11: ...rce address to the selected input and return the display to the source and destination addresses from which another data source address may be selected When a data source address is allocated to a lis...

Страница 12: ...ode irrespective of the numeric value When positioned as required operating the E button will enter the selection and return to the dP prompt in the edit sub menu 6 4 9 Configuration of bargraph displ...

Страница 13: ...sed access code will be activated when the transmitter is returned to the display mode If the access code is lost please contact BEKA associates 6 4 12 Change from fieldbus listener to fieldbus node t...

Страница 14: ...nds the model number followed by the firmware version will be displayed prior to entering the display mode 7 2 Fault finding after commissioning ENSURE PLANT SAFETY BEFORE STARTING MAINTENANCE Live ma...

Страница 15: ...lf adhesive escutcheon ensure that the gasket is correctly positioned before reassembling the instrument enclosure 8 2 Tag plate The BA444DF P can be supplied with a blank or custom laser marked stain...

Страница 16: ...efer to over 5mm thick EN 60079 14 At an ambient temperature between 20 and 60o C The Indicator may be connected to any intrinsically safe segment providing The device powering the fieldbus segment is...

Страница 17: ...name and location IECEx dust approval information is also shown non European certification information may also be included The label includes boxed areas which should be marked by the installer to s...

Страница 18: ...mply with the Canadian Electrical Code C22 2 and with BEKA associates Control Drawing CI410 12 which is attached to this Appendix The FM and cFM entity parameters are identical to the ATEX parameters...

Страница 19: ...19...

Страница 20: ...20...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...24...

Страница 25: ...25...

Страница 26: ...allation requirements for both gas and dust approvals The ATEX installation requirements specified in the main section and in Appendix 1 of this manual may therefore be used for IECEx installations bu...

Отзывы: