To enter the ‘oFFSt’ function press
P
which will
reveal the existing offset with one digit flashing.
Again the flashing digit may be changed by
operating the
▼
or
▲
button and the
P
button will
move control to the next digit or to the decimal
point. When ‘oFFSt’ has been set to the required
value operating the
E
button will enter the selection
and return to the ‘oFFSt’ prompt in the sub-menu.
Three operations of the
E
button will return to the
‘Edit’ function in the listener configuration menu.
5.3.12 Access code for listener configuration
menu. ‘CodE’
Access to the listener menu may be protected by a
four digit security code which must be entered to
gain access. New instruments are supplied
configured with the default code 0000 which
disables this protection and allows unrestricted
access to the configuration menu.
To enter a new access code select ‘CodE’ in the
listener configuration menu by operating the
▼
or
▲
button. To enter the function press
P
which will
reveal the current access code with one digit
flashing. The code may be changed using the
▼
or
▲
button to adjust the flashing digit and the
P
button to move control to the next digit. When the
required code has been selected, press
E
to enter
the selection and return to the ‘CodE’ prompt in the
listener configuration menu. The revised access
code will be activated when the indicator is
returned to the display mode.
If the access code is lost please contact BEKA
associates.
5.3.13 Change from listener to node ‘tYPE’
This function enables the instrument to be
changed from a fieldbus listener to a fieldbus node
by selecting ‘tYPE’ in the listener configuration
menu using the
▼
or
▲
button. To enter the
function press
P
which will show that the
instrument is configured as a fieldbus listener, to
change to a fieldbus node press the
▼
or
▲
button
which will toggle the display to ‘nodE’ To prevent
accidental changes this request must be
confirmed by operating the
P
button and entering
‘5urE’. The instrument will display ‘0000’ with the
first digit flashing, using the
▼
or
▲
button set the
flashing digit to ‘5’ and press the
P
button to move
control to the next digit which should be set to ‘u’.
When the four letters of ‘5urE’ have been entered,
operating the
E
button will cause the instrument to
restart as a fieldbus node in the display mode.
CAUTION
All the instrument’s listener configuration
will be lost when it is changed from a
fieldbus listener to a fieldbus node.
5.3.14 Reset the indicator to listener factory
defaults ‘rESEt’
The BA644DF-F indicator may be reset to the
listener factory defaults shown below:
Security Code
0000 (disabled)
For each of the eight inputs:
Input enable
Off
Decimal point
Auto (maximum resolution)
Bar Type
Left
Bar lower limit
0.0
Bar Upper limit
100.0
Gain
1.0
Offset
0.0
To reset the BA644DF-F indicator to the listener
factory defaults select ‘rESEt’ in the listener
configuration menu by operating the
▼
or
▲
button. To enter the function press
P
which will
reveal ‘0000’ with the left hand digit flashing. To
prevent accidental use of this function, ‘5urE’ must
be entered to confirm that the instrument is to be
reset.
Using the
▼
or
▲
button set the flashing digit to ‘5’
and press the
P
button to move control to the next
digit which should be set to ‘u’. When the four
letters of ‘5urE’ have been entered operating the
E
button will reset the BA644DF-F to the factory
defaults. Any existing configuration and
addresses will be lost when the indicator is reset.