Altering the machine parameters
Parameter 30:
Set the main speed
Setting range:
0 - 6500
Parameter 31:
Manual sewing on/ off
Setting range:
0 / 1
Parameter 32:
Number of stitches how long the table blowing
remains switched on
Setting range:
0 …400 stitches
Parameter 33:
Number of stitches until the automatic start engages
after the sewing start
Setting range:
0 ...
Parameter 34:
Number of stitches until the contour guide lowers
Setting range:
0 …400 stitches
Parameter 35:
Number of stitches until the contour guide retracts
laterally
Setting range:
0 …400 stitches
Parameter 36:
Number of stitches until the feeding unit lowers
Setting range: 0 ...400
Parameter 37:
Start mode contour modulation
1 = front, left
2 = rear, right
3 = rear, left
Setting range:
Modes 1, 2, 3
Parameter 60:
Soft start speed
Setting range:
500 ...5000
Parameter 61:
Switch the soft start on or off
Setting range:
0 / 1
Parameter 76:
Switch the start on or off via light barrier
Setting range:
0 / 1
Parameter 77:
Switch the autostart on or off
Setting range:
0 / 1
Parameter 78:
Number of stitches until the autostart starts
Setting range:
0 ...400 stitches