Setting the ejector roller
Via this parameter the ejector roller is set.
Parameter 16:
Number of stitches how long the seam chain
is sucked (seam beginning)
Setting range:
0....120
Parameter 17:
Switch the stacker on or off
Setting range:
0 / 1
Parameter 20:
Number of stitches when the ejector roller lowers
Setting range:
0 …400 stitches
Parameter 21:
Number of stitches how long the ejector roller is
switched on
Setting range:
0 …400 stitches
Parameter 22:
Number of stitches after “light barrier bright”, until
the ejector roller stops
Setting range:
0 …30 stitches
Parameter 23:
Time how long the ejector roller is active
Setting range:
0 …1000
Parameter 47:
Time of the stacker movement
Input:
0 …2000
Parameter 53:
Time when the ejector roller lifts
Setting range:
0 …2000
Setting the puller
Via this parameter the puller is set.
Parameter 26:
Number of stitches when the puller lowers
Setting range:
0 …400 stitches
Parameter 27:
Number of stitches how long the puller remains
lowered
Setting range:
0 …400 stitches
Parameter 51:
Puller speed
lower value = increased puller speed
higher value = lower puller speed
Setting range:
400 … 1000
Parameter 100:
Number of stitches how long the puller lifts
Setting range:
0...400 stitches